Biocompatibility and Inflammatory Potential of Titanium Alloys Cultivated with Human Osteoblasts, Fibroblasts and Macrophages

Overview
Publisher MDPI
Date 2017 Aug 5
PMID 28772412
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

The biomaterials used to maintain or replace functions in the human body consist mainly of metals, ceramics or polymers. In orthopedic surgery, metallic materials, especially titanium and its alloys, are the most common, due to their excellent mechanical properties, corrosion resistance, and biocompatibility. Aside from the established Ti6Al4V alloy, shape memory materials such as nickel-titanium (NiTi) have risen in importance, but are also discussed because of the adverse effects of nickel ions. These might be reduced by specific surface modifications. In the present in vitro study, the osteoblastic cell line MG-63 as well as primary human osteoblasts, fibroblasts, and macrophages were cultured on titanium alloys (forged Ti6Al4V, additive manufactured Ti6Al4V, NiTi, and Diamond-Like-Carbon (DLC)-coated NiTi) to verify their specific biocompatibility and inflammatory potential. Additive manufactured Ti6Al4V and NiTi revealed the highest levels of metabolic cell activity. DLC-coated NiTi appeared as a suitable surface for cell growth, showing the highest collagen production. None of the implant materials caused a strong inflammatory response. In general, no distinct cell-specific response could be observed for the materials and surface coating used. In summary, all tested titanium alloys seem to be biologically appropriate for application in orthopedic surgery.

Citing Articles

Multifunctional coatings of nickel-titanium implant toward promote osseointegration after operation of bone tumor and clinical application: a review.

Du T, Liu J, Dong J, Xie H, Wang X, Yang X Front Bioeng Biotechnol. 2024; 12:1325707.

PMID: 38444648 PMC: 10912669. DOI: 10.3389/fbioe.2024.1325707.


Feasibility of a Shape-Memory-Alloy-Actuator System for Modular Acetabular Cups.

Rotsch C, Kemter-Esser K, Dohndorf J, Knothe M, Drossel W, Heyde C Bioengineering (Basel). 2024; 11(1).

PMID: 38247952 PMC: 10813518. DOI: 10.3390/bioengineering11010075.


Titanium alloys with varying surface micro-area potential differences have antibacterial abilities and a favorable cellular response.

Wang C, Hou Y, Fu S, Zhang E, Zhang Z, Bai B Clin Oral Investig. 2023; 27(9):4957-4971.

PMID: 37329465 DOI: 10.1007/s00784-023-05115-x.


In Vitro Evaluation of the Potential Anticancer Properties of Cu-Based Shape Memory Alloys.

Lazic M, Lazic M, Milasin J, Popovic D, Majeric P, Rudolf R Materials (Basel). 2023; 16(7).

PMID: 37049144 PMC: 10095799. DOI: 10.3390/ma16072851.


The development of novel bioactive porous titanium as a bone reconstruction material.

Doi K, Kobatake R, Makihara Y, Oki Y, Umehara H, Kubo T RSC Adv. 2022; 10(38):22684-22690.

PMID: 35514562 PMC: 9054584. DOI: 10.1039/d0ra03202f.


References
1.
Ryhanen J, Kallioinen M, Tuukkanen J, Lehenkari P, Junila J, Niemela E . Bone modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation. Biomaterials. 1999; 20(14):1309-17. DOI: 10.1016/s0142-9612(99)00032-0. View

2.
Lohmann C, Bonewald L, Sisk M, Sylvia V, Cochran D, Dean D . Maturation state determines the response of osteogenic cells to surface roughness and 1,25-dihydroxyvitamin D3. J Bone Miner Res. 2000; 15(6):1169-80. DOI: 10.1359/jbmr.2000.15.6.1169. View

3.
Fili P, Lausmaa J, Musialek J, Mazanec K . Structure and surface of TiNi human implants. Biomaterials. 2001; 22(15):2131-8. DOI: 10.1016/s0142-9612(00)00404-x. View

4.
Kapanen A, Ryhanen J, Danilov A, Tuukkanen J . Effect of nickel-titanium shape memory metal alloy on bone formation. Biomaterials. 2001; 22(18):2475-80. DOI: 10.1016/s0142-9612(00)00435-x. View

5.
Kapanen A, Ilvesaro J, Danilov A, Ryhanen J, Lehenkari P, Tuukkanen J . Behaviour of nitinol in osteoblast-like ROS-17 cell cultures. Biomaterials. 2002; 23(3):645-50. DOI: 10.1016/s0142-9612(01)00143-0. View