» Articles » PMID: 28735790

Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 2017 Jul 25
PMID 28735790
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: A ferrule on anterior endodontic-treated teeth has been evaluated using clinical trials, in vitro tests, and finite element analysis (FEA). The patient-specific FEA with a nonuniform ferrule and nonlinear contact biting load associated with clinical validation can be used to predict failure.

Methods: A patient was selected with both maxillary central incisors with different ferrule designs who received endodontic treatment and restoration using a fiber post, composite core, and computer aided design and computer aided manufacturing lithium disilicate ceramic crowns. Strain gauges were attached to the buccal surfaces of both teeth to record ceramic strain during bite force recording for FEA validation. Cone-beam computed tomographic imaging was performed, and the Digital Imaging and Communication in Medicine files were exported to Mimics, 3-Matic (Materialise, Leuven, Belgium) and Patran (MSC Software, Santa Ana, CA) software to create a patient-specific FEA model. Bite load was applied using contact load applied by antagonist teeth (155 N). Mechanical properties were obtained from the literature. Modified von Mises equivalent stress was used for stress evaluation.

Results: Stresses on the dentin and fiber post on the left incisor, which had a nonuniform ferrule, were higher compared with the right incisor. The strain values recorded for the right central incisor (strain gauge =79.9 ± 3.8 μS and FEA = 69.5 μS) and the left central incisor (strain gauge = 83.5 ± 5.3 μS and FEA = 73.9 μS) validate the FEA analysis.

Conclusions: FEA was validated with in vivo strain values measured at the buccal crown surfaces, supporting that the stress levels were realistic for investigation of the clinical performance of fiber posts. Maintaining a uniform ferrule was more favorable than a localized higher ferrule.

Citing Articles

Evaluation of the forces applied by rubber dam clamps on mandibular first molar teeth with different endodontic access cavities: a 3D FEA study.

Eskibaglar M, Erdem S, Eskibaglar B, Kaman M PeerJ. 2024; 12:e17921.

PMID: 39210915 PMC: 11361261. DOI: 10.7717/peerj.17921.


Biomechanical impact of labiolingual diameter on endodontically treated anterior teeth with crown restoration under occlusal loading.

Liang M, Zeyong L, Li Y, Chen Q, Meng X J Appl Oral Sci. 2024; 32:e20230439.

PMID: 38896638 PMC: 11182641. DOI: 10.1590/1678-7757-2023-0439.


Survival of severely compromised endodontically treated teeth restored with or without a fiber glass post.

Ribeiro M, de Oliveira G, Oliveira H, Mendoza L, de Melo C, Peres T J Appl Oral Sci. 2023; 31:e20230241.

PMID: 37909530 PMC: 10609643. DOI: 10.1590/1678-7757-2023-0241.


In-Vitro Comparison of Fracture Strength of Endocrowns and Overlays in Endodontically Treated Teeth Manufactured with Monolithic Lithium Disilicate and Zirconia.

Veselinova M, Diamantopoulou S, Paximada C, Papazoglou E J Funct Biomater. 2023; 14(8).

PMID: 37623666 PMC: 10455451. DOI: 10.3390/jfb14080422.


Precision medicine using patient-specific modelling: state of the art and perspectives in dental practice.

Lahoud P, Jacobs R, Boisse P, EzEldeen M, Ducret M, Richert R Clin Oral Investig. 2022; 26(8):5117-5128.

PMID: 35687196 DOI: 10.1007/s00784-022-04572-0.