Cardiac Cycle Efficiency and Dicrotic Pressure Variations: New Parameters for Fluid Therapy: An Observational Study
Overview
Authors
Affiliations
Background: During a fluid challenge, the changes in cardiac performance and peripheral circulatory tone are closely related to the position of the ventricle on the Frank-Starling curve. Some patients have a good haemodynamic response to a fluid challenge, others hardly any response. The early haemodynamic effects of a fluid challenge could predict the final response before the entire fluid volume has been administered.
Objective: To assess whether a multivariate logistic regression model, including pulse pressure variation (PPV), cardiac cycle efficiency (CCE), arterial elastance and the difference between the dicrotic pressure and both systolic and mean arterial pressure (SAP - Pdic and MAP - Pdic) can predict cardiac responsiveness early during a fluid challenge in comparison with the standard procedure described elsewhere.
Design: Observational study.
Setting: Elective surgical patients undergoing laparotomy, enrolled in two Italian University Hospitals.
Patients: Fifty adult surgical patients, ventilated with a lung protective strategy, were enrolled and data from 46 were analysed.
Interventions: A fluid challenge consisting of 500 ml of crystalloid infused over 10 min.
Main Outcome Measures And Analysis: The changes in CCE, arterial elastance, SAP - Pdic and MAP - Pdic were compared using analysis of variance. A multivariate logistic regression analysis utilising baseline values and the first minute measuring a variation statistically significant for the considered variables.
Results: At baseline, PPV correctly identified 70% of patients (89% of non-responders; 42% of responders). The model, including baseline PPV, ΔCCE and ΔSAP - Pdic, correctly identified the efficiency of fluid challenge in 87% of patients (84.2% of responders; 92.5 of non-responders) after 5 min from fluid challenge infusion.
Conclusion: In this pilot study conducted in a population of surgical patients mechanically ventilated with a VT less than 8 ml kg, a dynamic model of fluid challenge assessment, including PPV, ΔCCE and ΔSAP - Pdic, enhances the prediction of fluid challenge response after 5 min of a 10-min administration.
Trial Registration: ACTRN12616001479493.
Giacomelli E, Dorigo W, Romano S, Casini A, Giglioli C, Papini C Acta Med Acad. 2024; 53(1):10-23.
PMID: 38984696 PMC: 11242536. DOI: 10.5644/ama2006-124.442.
Abdullah T, Gokduman H, Eniste I, Atasever A, Ali A, Ozcan F Turk J Med Sci. 2024; 53(5):1224-1233.
PMID: 38813019 PMC: 10763793. DOI: 10.55730/1300-0144.5688.
Messina A, Caporale M, Calabro L, Lionetti G, Bono D, Matronola G Crit Care. 2023; 27(1):431.
PMID: 37940953 PMC: 10631038. DOI: 10.1186/s13054-023-04706-0.
Adembri C, Ungar A, Cappellini I, Romano S Methods Protoc. 2023; 6(4).
PMID: 37489434 PMC: 10366866. DOI: 10.3390/mps6040067.
Xie S, Han D, Chen G, Pan S Medicine (Baltimore). 2023; 101(49):e31795.
PMID: 36626414 PMC: 9750656. DOI: 10.1097/MD.0000000000031795.