» Articles » PMID: 28593931

Performance Characterization of a 3D Liquid Scintillation Detector for Discrete Spot Scanning Proton Beam Systems

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2017 Jun 9
PMID 28593931
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Existing systems for proton beam dosimetry are limited in their ability to provide a complete, accurate, and detailed account of volumetric dose distribution. In this work, we describe the design and development of a portable, fast, and reusable liquid scintillator-based three-dimensional (3D) optical detection system for use in proton therapy. Our long-term goal is to use this system clinically for beam characterization, dosimetry, and quality assurance studies of discrete spot scanning proton beam systems. The system used a 20  ×  20  ×  20 cm liquid scintillator volume. Three mutually orthogonal cameras surrounding this volume captured scintillation photons emitted in response to the proton beams. The cameras exhibited a mean spatial resolution of 0.21 mm over the complete detection volume and a temporal resolution of 11 ms. The system is shown to be capable of capturing all 94 beam energies delivered by a synchrotron and performing rapid beam range measurements with a mean accuracy of 0.073  ±  0.030 mm over all energies. The range measurement uncertainty for doses less than 1 cGy was found to be  ±0.355 mm, indicating high precision for low dose detection. Finally, we demonstrated that using multiple cameras allowed for the precise locations of the delivered beams to be tracked in 3D. We conclude that this detector is capable of real-time and accurate tracking of dynamic spot beam deliveries in 3D. The high-resolution light profiles it generates will be useful for future 3D construction of dose maps.

Citing Articles

Development of a three-dimensional scintillation detector for pencil beam verification in proton therapy patient-specific quality assurance.

Frelin A, Daviau G, Bui M, Fontbonne C, Fontbonne J, Lebhertz D Med Phys. 2024; 51(12):9318-9329.

PMID: 39255360 PMC: 11656293. DOI: 10.1002/mp.17388.


High-Density Glass Scintillators for Proton Radiography-Relative Luminosity, Proton Response, and Spatial Resolution.

Stolen E, Fullarton R, Hein R, Conner R, Jacobsohn L, Collins-Fekete C Sensors (Basel). 2024; 24(7).

PMID: 38610351 PMC: 11014246. DOI: 10.3390/s24072137.


Optically stimulated luminescence in state-of-the-art LYSO:Ce scintillators enables high spatial resolution 3D dose imaging.

Jensen M, Nyemann J, Muren L, Julsgaard B, Balling P, Turtos R Sci Rep. 2022; 12(1):8301.

PMID: 35585168 PMC: 9117671. DOI: 10.1038/s41598-022-12255-9.


A novel proton-integrating radiography system design using a monolithic scintillator detector: experimental studies.

Darne C, Robertson D, Alsanea F, Collins-Fekete C, Beddar S Nucl Instrum Methods Phys Res A. 2022; 1027.

PMID: 35221402 PMC: 8872121. DOI: 10.1016/j.nima.2021.166077.


Ultra-high dose rate electron beams and the FLASH effect: From preclinical evidence to a new radiotherapy paradigm.

Schuler E, Acharya M, Montay-Gruel P, Loo Jr B, Vozenin M, Maxim P Med Phys. 2022; 49(3):2082-2095.

PMID: 34997969 PMC: 9032195. DOI: 10.1002/mp.15442.


References
1.
Kroll F, Pawelke J, Karsch L . Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography. Med Phys. 2013; 40(8):082104. DOI: 10.1118/1.4813898. View

2.
Beddar S, Archambault L, Sahoo N, Poenisch F, Chen G, Gillin M . Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams. Med Phys. 2009; 36(5):1736-43. PMC: 2832031. DOI: 10.1118/1.3117583. View

3.
Ingram W, Robertson D, Beddar S . Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy. Nucl Instrum Methods Phys Res A. 2015; 776:15-20. PMC: 4332394. DOI: 10.1016/j.nima.2014.12.004. View

4.
Doran S, Gorjiara T, Kacperek A, Adamovics J, Kuncic Z, Baldock C . Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters. Phys Med Biol. 2015; 60(2):709-26. PMC: 5390951. DOI: 10.1088/0031-9155/60/2/709. View

5.
Archambault L, Poenisch F, Sahoo N, Robertson D, Lee A, Gillin M . Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system. Med Phys. 2012; 39(3):1239-46. PMC: 3292596. DOI: 10.1118/1.3681948. View