» Articles » PMID: 28471242

Low Radiation Dose in Computed Tomography: the Role of Iodine

Overview
Journal Br J Radiol
Specialty Radiology
Date 2017 May 5
PMID 28471242
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration.

Citing Articles

Innovation and Optimization of Contrast Media Administration in Computed Tomography.

Caruso D Korean J Radiol. 2025; 26(3):210-212.

PMID: 39999960 PMC: 11865897. DOI: 10.3348/kjr.2024.1159.


Composite Iodine-gold Nanoparticles as a Contrast Agent in Computed Tomography.

Haghighi R, Zarei F, Moshiri S, Jafari A, Chatterjee S, Akondi V J Med Phys. 2024; 49(3):448-455.

PMID: 39526145 PMC: 11548064. DOI: 10.4103/jmp.jmp_126_23.


Computed tomography image quality in patients with primary hepatocellular carcinoma: intraindividual comparison of contrast agent concentrations.

Peng F, Luo C, Ning X, Xiao F, Guan K, Tang C Front Med (Lausanne). 2024; 11:1460505.

PMID: 39478815 PMC: 11521877. DOI: 10.3389/fmed.2024.1460505.


Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography.

Yuan D, Wang L, Lyu P, Zhang Y, Gao J, Liu J Int J Cardiovasc Imaging. 2024; 40(6):1377-1388.

PMID: 38722507 DOI: 10.1007/s10554-024-03113-y.


Feasibility of Low-Dose and Low-Contrast Media Volume Approach in Computed Tomography Cardiovascular Imaging Reconstructed with Model-Based Algorithm.

Ippolito D, Porta M, Maino C, Riva L, Ragusi M, Giandola T Tomography. 2024; 10(2):286-298.

PMID: 38393291 PMC: 10891780. DOI: 10.3390/tomography10020023.


References
1.
Zheng M, Wu Y, Wei M, Liu Y, Zhao H, Li J . Low-concentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition. Acad Radiol. 2014; 22(2):195-202. DOI: 10.1016/j.acra.2014.07.025. View

2.
Kanematsu M, Goshima S, Kawai N, Kondo H, Miyoshi T, Watanabe H . Low-Iodine-Load and Low-Tube-Voltage CT Angiographic Imaging of the Kidney by Using Bolus Tracking with Saline Flushing. Radiology. 2014; 275(3):832-40. DOI: 10.1148/radiol.14141457. View

3.
Fleischmann D, Rubin G . Quantification of intravenously administered contrast medium transit through the peripheral arteries: implications for CT angiography. Radiology. 2005; 236(3):1076-82. DOI: 10.1148/radiol.2363041392. View

4.
Cho E, Yu J, Ahn J, Kim J, Chung J, Lee H . CT angiography of the renal arteries: comparison of lower-tube-voltage CTA with moderate-concentration iodinated contrast material and conventional CTA. AJR Am J Roentgenol. 2012; 199(1):96-102. DOI: 10.2214/AJR.11.7450. View

5.
Watanabe H, Kanematsu M, Miyoshi T, Goshima S, Kondo H, Moriyama N . Improvement of image quality of low radiation dose abdominal CT by increasing contrast enhancement. AJR Am J Roentgenol. 2010; 195(4):986-92. DOI: 10.2214/AJR.10.4456. View