» Articles » PMID: 2846633

Simultaneous Detection of Antibodies to Cytomegalovirus and Herpes Simplex Virus by Using Flow Cytometry and a Microsphere-based Fluorescence Immunoassay

Overview
Specialty Microbiology
Date 1988 Oct 1
PMID 2846633
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

A sensitive assay for the simultaneous detection of anti-cytomegalovirus and anti-herpes simplex virus antibodies was developed. Two different sizes of polystyrene microspheres were coated with purified viral antigens. Human antiviral antibodies were detected with a biotin-streptavidin amplification procedure with phycoerythrin as the fluorescent label. Microsphere-associated fluorescence was quantitated with a flow cytometer. Sixteen percent of samples initially scored as seronegative for cytomegalovirus and 35% of samples initially scored as seronegative for herpes simplex virus by conventional assays were clearly found positive by the microsphere technique. This flow cytometric assay can simultaneously detect several specific antibodies at levels which are below the sensitivity of standard assays. The dynamic range of this assay is at least sixfold greater than that of enzyme immunoassays. This technique is amenable to numerous serologic assays and could greatly expand the clinical laboratory applications of flow cytometry.

Citing Articles

Microsphere integrated microfluidic disk: synergy of two techniques for rapid and ultrasensitive dengue detection.

Hosseini S, Aeinehvand M, Uddin S, Benzina A, Rothan H, Yusof R Sci Rep. 2015; 5:16485.

PMID: 26548806 PMC: 4637926. DOI: 10.1038/srep16485.


Effect of serum heat-inactivation and dilution on detection of anti-WNV antibodies in mice by West Nile virus E-protein microsphere immunoassay.

Namekar M, Kumar M, OConnell M, Nerurkar V PLoS One. 2012; 7(9):e45851.

PMID: 23049879 PMC: 3457982. DOI: 10.1371/journal.pone.0045851.


Surface Functionalization Methods to Enhance Bioconjugation in Metal-Labeled Polystyrene Particles.

Abdelrahman A, Thickett S, Liang Y, Ornatsky O, Baranov V, Winnik M Macromolecules. 2011; 44(12):4801-4813.

PMID: 21799543 PMC: 3143033. DOI: 10.1021/ma200582q.


An integrated microfluidic system for isolation, counting, and sorting of hematopoietic stem cells.

Wu H, Hsu R, Lin C, Hwang S, Lee G Biomicrofluidics. 2010; 4(2).

PMID: 20697577 PMC: 2917870. DOI: 10.1063/1.3454767.


Multiplexed and microparticle-based analyses: quantitative tools for the large-scale analysis of biological systems.

Nolan J, Mandy F Cytometry A. 2006; 69(5):318-25.

PMID: 16604537 PMC: 2200865. DOI: 10.1002/cyto.a.20266.


References
1.
Fraser C, Melendez L, Simeone T . Specificity differentiation of herpes simplex virus types 1 and 2 by indirect immunofluorescence. J Infect Dis. 1974; 130(1):63-6. DOI: 10.1093/infdis/130.1.63. View

2.
Krowka J, Stites D, Mills J, Hollander H, McHugh T, Busch M . Effects of interleukin 2 and large envelope glycoprotein (gp 120) of human immunodeficiency virus (HIV) on lymphocyte proliferative responses to cytomegalovirus. Clin Exp Immunol. 1988; 72(2):179-85. PMC: 1541530. View

3.
Adler S, LAWRENCE L, Baggett J, BIRO V, Sharp D . Prevention of transfusion-associated cytomegalovirus infection in very low-birthweight infants using frozen blood and donors seronegative for cytomegalovirus. Transfusion. 1984; 24(4):333-5. DOI: 10.1046/j.1537-2995.1984.24484275576.x. View

4.
Gilljam G, Sundqvist V, Linde A, Pihlstedt P, EKLUND A, Wahren B . Sensitive analytic ELISAs for subclass herpes virus IgG. J Virol Methods. 1985; 10(3):203-14. DOI: 10.1016/0166-0934(85)90061-8. View

5.
Saunders G, Jett J, Martin J . Amplified flow-cytometric separation-free fluorescence immunoassays. Clin Chem. 1985; 31(12):2020-3. View