» Articles » PMID: 28453556

Characterization of Interfragmentary Motion Associated with Common Osteosynthesis Devices for Rat Fracture Healing Studies

Overview
Journal PLoS One
Date 2017 Apr 29
PMID 28453556
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies.

Citing Articles

Surgical Classification for Preclinical Rat Femoral Bone Defect Model: Standardization Based on Systematic Review, Anatomical Analysis and Virtual Surgery.

Sun Y, Helmholz H, Willumeit-Romer R Bioengineering (Basel). 2022; 9(9).

PMID: 36135022 PMC: 9495991. DOI: 10.3390/bioengineering9090476.


Suture anchor fixation may be an alternative to tension band wiring in olecranon fractures: Finite element analysis.

Kuru T, Mutlu I Jt Dis Relat Surg. 2020; 31(2):238-245.

PMID: 32584720 PMC: 7489162. DOI: 10.5606/ehc.2020.73586.


A methodology for the generation and non-destructive characterisation of transverse fractures in long bones.

Zapata-Cornelio F, Jin Z, Barton D, Jones A, Wilcox R Bone Rep. 2018; 8:221-228.

PMID: 29955641 PMC: 6020270. DOI: 10.1016/j.bonr.2018.04.007.


Whole bone testing in small animals: systematic characterization of the mechanical properties of different rodent bones available for rat fracture models.

Prodinger P, Foehr P, Burklein D, Bissinger O, Pilge H, Kreutzer K Eur J Med Res. 2018; 23(1):8.

PMID: 29444703 PMC: 5813325. DOI: 10.1186/s40001-018-0307-z.

References
1.
Heiner D, Meyer M, Frick S, Kellam J, Fiechtl J, Meyer Jr R . Gene expression during fracture healing in rats comparing intramedullary fixation to plate fixation by DNA microarray. J Orthop Trauma. 2006; 20(1):27-38. DOI: 10.1097/01.bot.0000184143.90448.aa. View

2.
Krischak G, Augat P, Blakytny R, Claes L, Kinzl L, Beck A . The non-steroidal anti-inflammatory drug diclofenac reduces appearance of osteoblasts in bone defect healing in rats. Arch Orthop Trauma Surg. 2007; 127(6):453-8. DOI: 10.1007/s00402-007-0288-9. View

3.
Willie B, Adkins K, Zheng X, Simon U, Claes L . Mechanical characterization of external fixator stiffness for a rat femoral fracture model. J Orthop Res. 2008; 27(5):687-93. DOI: 10.1002/jor.20792. View

4.
Histing T, Holstein J, Garcia P, Matthys R, Kristen A, Claes L . Ex vivo analysis of rotational stiffness of different osteosynthesis techniques in mouse femur fracture. J Orthop Res. 2009; 27(9):1152-6. DOI: 10.1002/jor.20849. View

5.
van der Stok J, Koolen M, Jahr H, Kops N, Waarsing J, Weinans H . Chondrogenically differentiated mesenchymal stromal cell pellets stimulate endochondral bone regeneration in critical-sized bone defects. Eur Cell Mater. 2014; 27:137-48. DOI: 10.22203/ecm.v027a11. View