» Articles » PMID: 28344619

The Watchman FLX - a New Device for Left Atrial Appendage Occlusion - Design, Potential Benefits and First Clinical Experience

Overview
Publisher Termedia
Date 2017 Mar 28
PMID 28344619
Citations 11
Authors
Affiliations
Soon will be listed here.
Citing Articles

Quantitative considerations for choosing between Amulet and Watchman FLX and management of device related complications.

Kushnir A, Barbhaiya C, Jankelson L, Holmes D, Aizer A, Park D J Interv Card Electrophysiol. 2025; .

PMID: 39939509 DOI: 10.1007/s10840-025-02011-0.


A Comprehensive Review of Percutaneous and Surgical Left Atrial Appendage Occlusion.

Swieczkowski M, Dabrowski E, Muszynski P, Pogorzelski P, Jemielita P, Dudzik J J Cardiovasc Dev Dis. 2024; 11(8).

PMID: 39195142 PMC: 11354510. DOI: 10.3390/jcdd11080234.


Device-Associated Thrombus with Watchman FLX Left Atrial Appendage Closure Device: A Report of Two Cases.

Dhaduk N, Vainrib A, Bamira D, Ro R, Aizer A, Chinitz L CASE (Phila). 2023; 7(6):226-232.

PMID: 37396475 PMC: 10307589. DOI: 10.1016/j.case.2023.01.010.


Periprocedural outcome in patients undergoing left atrial appendage occlusion with the Watchman FLX device: The ITALIAN-FLX registry.

Berti S, De Caterina A, Grasso C, Casu G, Giacchi G, Pagnotta P Front Cardiovasc Med. 2023; 10:1115811.

PMID: 37180775 PMC: 10172664. DOI: 10.3389/fcvm.2023.1115811.


WATCHMAN FLX implantation with an extremely small left atrial appendage ostium.

Yano M, Egami Y, Nishino M, Tanouchi J Eur Heart J Case Rep. 2022; 6(2):ytac090.

PMID: 35295726 PMC: 8922692. DOI: 10.1093/ehjcr/ytac090.


References
1.
Holmes Jr D, Kar S, Price M, Whisenant B, Sievert H, Doshi S . Prospective randomized evaluation of the Watchman Left Atrial Appendage Closure device in patients with atrial fibrillation versus long-term warfarin therapy: the PREVAIL trial. J Am Coll Cardiol. 2014; 64(1):1-12. DOI: 10.1016/j.jacc.2014.04.029. View

2.
Reddy V, Holmes D, Doshi S, Neuzil P, Kar S . Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry. Circulation. 2011; 123(4):417-24. DOI: 10.1161/CIRCULATIONAHA.110.976449. View

3.
Lam S, Bertog S, Gafoor S, Vaskelyte L, Boehm P, Ho R . Left atrial appendage closure using the Amulet device: an initial experience with the second generation amplatzer cardiac plug. Catheter Cardiovasc Interv. 2014; 85(2):297-303. DOI: 10.1002/ccd.25644. View

4.
Reddy V, Mobius-Winkler S, Miller M, Neuzil P, Schuler G, Wiebe J . Left atrial appendage closure with the Watchman device in patients with a contraindication for oral anticoagulation: the ASAP study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology). J Am Coll Cardiol. 2013; 61(25):2551-6. DOI: 10.1016/j.jacc.2013.03.035. View

5.
Reddy V, Doshi S, Sievert H, Buchbinder M, Neuzil P, Huber K . Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) Trial. Circulation. 2013; 127(6):720-9. DOI: 10.1161/CIRCULATIONAHA.112.114389. View