An Automated Smartphone-based Diagnostic Assay for Point-of-care Semen Analysis
Overview
Science
Authors
Affiliations
Male infertility affects up to 12% of the world's male population and is linked to various environmental and medical conditions. Manual microscope-based testing and computer-assisted semen analysis (CASA) are the current standard methods to diagnose male infertility; however, these methods are labor-intensive, expensive, and laboratory-based. Cultural and socially dominated stigma against male infertility testing hinders a large number of men from getting tested for infertility, especially in resource-limited African countries. We describe the development and clinical testing of an automated smartphone-based semen analyzer designed for quantitative measurement of sperm concentration and motility for point-of-care male infertility screening. Using a total of 350 clinical semen specimens at a fertility clinic, we have shown that our assay can analyze an unwashed, unprocessed liquefied semen sample with <5-s mean processing time and provide the user a semen quality evaluation based on the World Health Organization (WHO) guidelines with ~98% accuracy. The work suggests that the integration of microfluidics, optical sensing accessories, and advances in consumer electronics, particularly smartphone capabilities, can make remote semen quality testing accessible to people in both developed and developing countries who have access to smartphones.
Artificial Intelligence in IVF Laboratories: Elevating Outcomes Through Precision and Efficiency.
Hew Y, Kutuk D, Duzcu T, Ergun Y, Basar M Biology (Basel). 2025; 13(12.
PMID: 39765654 PMC: 11727220. DOI: 10.3390/biology13120988.
Can Microfluidics Improve Sperm Quality? A Prospective Functional Study.
Meseguer F, Gimenez Rodriguez C, Rivera Egea R, Carrion Sisternas L, Remohi J, Meseguer M Biomedicines. 2024; 12(5).
PMID: 38791093 PMC: 11118748. DOI: 10.3390/biomedicines12051131.
Dincer M, Yentur S, Colakerol A, Cil G, Yazar R, Kandirali E Diagnostics (Basel). 2024; 14(7).
PMID: 38611602 PMC: 11011288. DOI: 10.3390/diagnostics14070689.
Microfluidic chip as a promising evaluation method in assisted reproduction: A systematic review.
Wu T, Wu Y, Yan J, Zhang J, Wang S Bioeng Transl Med. 2024; 9(2):e10625.
PMID: 38435817 PMC: 10905557. DOI: 10.1002/btm2.10625.
Advancing biological investigations using portable sensors for detection of sensitive samples.
Mir T, Wani A, Akhtar N, Katoch V, Shukla S, Kadam U Heliyon. 2023; 9(12):e22679.
PMID: 38089995 PMC: 10711145. DOI: 10.1016/j.heliyon.2023.e22679.