An Unusual Presentation of Catastrophic Failure of Hip Arthroplasty with a Thigh Mass

Overview
Publisher Elsevier
Date 2017 Mar 23
PMID 28326401
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

In the advent of increasing demand for total hip arthroplasty, surveillance of these patients is imperative to identify potential complications requiring revision surgery. This is especially important in the young population, as revision is usually necessary during their lifetime. We present a case of a young female patient with a history of total hip arthroplasty 17 years prior, who presented with left hip pain and anterior thigh mass. The prosthetic hip had progressed to catastrophic failure with the cobalt-chrome femoral head having eroded through the polyethylene and acetabular socket. This was associated with significant metal debris and large fluid collection in the thigh. The patient required complex revision surgery but could have had a much lesser procedure with earlier intervention.

Citing Articles

Wear debris in metal-on-metal bearings and modular junctions : What have we learned from the last decades?.

Knecht C, Polakof L, Behrens J, Goodman S Orthopadie (Heidelb). 2023; 52(3):206-213.

PMID: 36820850 DOI: 10.1007/s00132-023-04346-w.


Do Not Postpone Revision of Worn Conventional Liners in Ceramic-on-Polyethylene Total Hip Arthroplasty: A New Dramatic Failure.

Gehrke T, Citak M, Abdelaziz H Arthroplast Today. 2021; 10:108-113.

PMID: 34345640 PMC: 8319508. DOI: 10.1016/j.artd.2021.06.011.


Prosthetic femoral head erosion through an acetabular component treated with revision and implant preservation.

Kohn M, Fernando N Arthroplast Today. 2020; 6(1):9-13.

PMID: 32211468 PMC: 7083747. DOI: 10.1016/j.artd.2019.12.003.

References
1.
Baker D, Hastings R, Pruitt L . Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res. 1999; 46(4):573-81. DOI: 10.1002/(sici)1097-4636(19990915)46:4<573::aid-jbm16>3.0.co;2-a. View

2.
Engh Jr C, Hopper R, Engh C, McAuley J . Wear-through of a modular polyethylene liner: four case reports. Clin Orthop Relat Res. 2001; (383):175-82. DOI: 10.1097/00003086-200102000-00019. View

3.
Duffy G, Berry D, Rowland C, Cabanela M . Primary uncemented total hip arthroplasty in patients <40 years old: 10- to 14-year results using first-generation proximally porous-coated implants. J Arthroplasty. 2001; 16(8 Suppl 1):140-4. DOI: 10.1054/arth.2001.28716. View

4.
Harris W . Wear and periprosthetic osteolysis: the problem. Clin Orthop Relat Res. 2002; (393):66-70. DOI: 10.1097/00003086-200112000-00007. View

5.
Crowther J, Lachiewicz P . Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg Am. 2002; 84(5):729-35. DOI: 10.2106/00004623-200205000-00005. View