On the Reproducibility of Expert-operated and Robotic Ultrasound Acquisitions

Overview
Publisher Springer
Date 2017 Mar 22
PMID 28321804
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging.

Methods: Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface.

Results: After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements.

Conclusions: A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.

Citing Articles

Autonomous robotic ultrasound scanning system: a key to enhancing image analysis reproducibility and observer consistency in ultrasound imaging.

Lin X, Li M, Ruan S, Ke W, Zhang H, Huang H Front Robot AI. 2025; 12:1527686.

PMID: 39975565 PMC: 11835693. DOI: 10.3389/frobt.2025.1527686.


Towards autonomous robotic THz-based in vivo skin sensing: the PicoBot.

Dogra A, Jones D, Hernandez Serrano A, Chakraborty S, Young J, Page B Sci Rep. 2025; 15(1):4568.

PMID: 39915605 PMC: 11803113. DOI: 10.1038/s41598-025-88718-6.


Robotic Assisted Ultrasound-Guided Endovascular Stent Implantation in a Vascular Model.

Scheibert A, Preuss M, Osburg J, Ernst F, Kleemann M, Horn M Int J Med Robot. 2024; 20(6):e70005.

PMID: 39501897 PMC: 11670045. DOI: 10.1002/rcs.70005.


Autonomous ultrasound scanning robotic system based on human posture recognition and image servo control: an application for cardiac imaging.

Tang X, Wang H, Luo J, Jiang J, Nian F, Qi L Front Robot AI. 2024; 11:1383732.

PMID: 38774468 PMC: 11106497. DOI: 10.3389/frobt.2024.1383732.


A fully autonomous robotic ultrasound system for thyroid scanning.

Su K, Liu J, Ren X, Huo Y, Du G, Zhao W Nat Commun. 2024; 15(1):4004.

PMID: 38734697 PMC: 11519952. DOI: 10.1038/s41467-024-48421-y.


References
1.
Lasso A, Heffter T, Rankin A, Pinter C, Ungi T, Fichtinger G . PLUS: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans Biomed Eng. 2014; 61(10):2527-37. PMC: 4437531. DOI: 10.1109/TBME.2014.2322864. View

2.
Fakhry C, Agrawal N, Califano J, Messing B, Liu J, Saunders J . The use of ultrasound in the search for the primary site of unknown primary head and neck squamous cell cancers. Oral Oncol. 2014; 50(7):640-5. PMC: 4696034. DOI: 10.1016/j.oraloncology.2014.03.015. View

3.
Cooper D, Doherty G, Haugen B, Hauger B, Kloos R, Lee S . Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid. 2009; 19(11):1167-214. DOI: 10.1089/thy.2009.0110. View

4.
Vinayak S, Sande J . Avoiding unnecessary fine-needle aspiration cytology by accuractely predicting the benign nature of thyroid nodules using ultrasound. J Clin Imaging Sci. 2012; 2:23. PMC: 3352615. DOI: 10.4103/2156-7514.95446. View

5.
Hennersperger C, Fuerst B, Virga S, Zettinig O, Frisch B, Neff T . Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility Study. IEEE Trans Med Imaging. 2016; 36(2):538-548. DOI: 10.1109/TMI.2016.2620723. View