SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2017 Mar 10
PMID 28273818
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

Citing Articles

Multi-Sensor Wearable Health Device Framework for Real-Time Monitoring of Elderly Patients Using a Mobile Application and High-Resolution Parameter Estimation.

Pinheiro G, Miranda R, Praciano B, Santos G, Mendonca F, Javidi E Front Hum Neurosci. 2022; 15:750591.

PMID: 35111004 PMC: 8802457. DOI: 10.3389/fnhum.2021.750591.


Machine-intelligence for developing a potent signature to predict ovarian response to tailor assisted reproduction technology.

Yan S, Jin W, Ding J, Yin T, Zhang Y, Yang J Aging (Albany NY). 2021; 13(13):17137-17154.

PMID: 33999860 PMC: 8312467. DOI: 10.18632/aging.203032.


Hip Positioning and Sitting Posture Recognition Based on Human Sitting Pressure Image.

Wan Q, Zhao H, Li J, Xu P Sensors (Basel). 2021; 21(2).

PMID: 33435362 PMC: 7826808. DOI: 10.3390/s21020426.


Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Nie L, Berckmans D, Wang C, Li B Sensors (Basel). 2020; 20(8).

PMID: 32316511 PMC: 7219037. DOI: 10.3390/s20082291.


Current progress of photoplethysmography and SPO for health monitoring.

Tamura T Biomed Eng Lett. 2019; 9(1):21-36.

PMID: 30956878 PMC: 6431353. DOI: 10.1007/s13534-019-00097-w.


References
1.
Liu T, Yao D . Removal of the ocular artifacts from EEG data using a cascaded spatio-temporal processing. Comput Methods Programs Biomed. 2006; 83(2):95-103. DOI: 10.1016/j.cmpb.2006.03.009. View

2.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

3.
Poh M, Swenson N, Picard R . Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography. IEEE Trans Inf Technol Biomed. 2010; 14(3):786-94. DOI: 10.1109/TITB.2010.2042607. View

4.
Kamal A, Harness J, Irving G, Mearns A . Skin photoplethysmography--a review. Comput Methods Programs Biomed. 1989; 28(4):257-69. DOI: 10.1016/0169-2607(89)90159-4. View

5.
Yan Y, Poon C, Zhang Y . Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution. J Neuroeng Rehabil. 2005; 2(1):3. PMC: 553999. DOI: 10.1186/1743-0003-2-3. View