» Articles » PMID: 28224425

Mechanism of Dynamic Near-infrared Fluorescence Cholangiography of Extrahepatic Bile Ducts and Applications in Detecting Bile Duct Injuries Using Indocyanine Green in Animal Models

Overview
Specialty General Medicine
Date 2017 Feb 23
PMID 28224425
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Fluorescence intraoperative cholangiography (IOC) is a potential alternative for identifying anatomical variation and preventing iatrogenic bile duct injuries by using the near-infrared probe indocyanine green (ICG). However, the dynamic process and mechanism of fluorescence IOC have not been elucidated in previous publications. Herein, the optical properties of the complex of ICG and bile, dynamic fluorescence cholangiography and iatrogenic bile duct injuries were investigated. The emission spectrum of ICG in bile peaked at 844 nm and ICG had higher tissue penetration. Extrahepatic bile ducts could fluoresce 2 min after intravenous injection, and the fluorescence intensity reached a peak at 8 min. In addition, biliary dynamics were observed owing to ICG excretion from the bile ducts into the duodenum. Quantitative analysis indicated that ICG-guided fluorescence IOC possessed a high signal to noise ratio compared to the surrounding peripheral tissue and the portal vein. Fluorescence IOC was based on rapid uptake of circulating ICG in plasma by hepatic cells, excretion of ICG into the bile and then its interaction with protein molecules in the bile. Moreover, fluorescence IOC was sensitive to detect bile duct ligation and acute bile duct perforation using ICG in rat models. All of the results indicated that fluorescence IOC using ICG is a valid alternative for the cholangiography of extrahepatic bile ducts and has potential for measurement of biliary dynamics.

Citing Articles

Fluorescence-guided Surgery for Hepatocellular Carcinoma: From Clinical Practice to Laboratories.

Xiao T, Chen D, Peng L, Li Z, Pan W, Dong Y J Clin Transl Hepatol. 2025; 13(3):216-232.

PMID: 40078203 PMC: 11894393. DOI: 10.14218/JCTH.2024.00375.


Indocyanine green real-time-guided laparoscopic duodenum-preserving pancreatic head resection.

Zhang Y, Zhang J, Jiang K, Wu W J Minim Access Surg. 2022; 18(4):632-634.

PMID: 36124475 PMC: 9632711. DOI: 10.4103/jmas.jmas_205_21.


Fine-scale visualizing the hierarchical structure of mouse biliary tree with fluorescence microscopy method.

Chen Y, Bai L, Zhou Y, Zhang X, Zhang J, Shi Y Biosci Rep. 2020; 40(5).

PMID: 32364232 PMC: 7218221. DOI: 10.1042/BSR20193757.


Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis.

Wu D, Xue D, Zhou J, Wang Y, Feng Z, Xu J Theranostics. 2020; 10(8):3636-3651.

PMID: 32206113 PMC: 7069080. DOI: 10.7150/thno.41127.


The role of indocyanine green fluoroscopy for intraoperative bile duct visualization during laparoscopic cholecystectomy: an observational cohort study in 70 patients.

Ambe P, Plambeck J, Fernandez-Jesberg V, Zarras K Patient Saf Surg. 2019; 13:2.

PMID: 30651756 PMC: 6330420. DOI: 10.1186/s13037-019-0182-8.


References
1.
Park S, Kim J, Jeon M, Song J, Kim C . In vivo photoacoustic and fluorescence cystography using clinically relevant dual modal indocyanine green. Sensors (Basel). 2014; 14(10):19660-8. PMC: 4239921. DOI: 10.3390/s141019660. View

2.
Veenstra B, Deal R, Redondo R, Daly S, Najman J, Myers J . Long-term efficacy of laparoscopic cholecystectomy for the treatment of biliary dyskinesia. Am J Surg. 2014; 207(3):366-70. DOI: 10.1016/j.amjsurg.2013.09.012. View

3.
Halata M, Berezin S . Biliary dyskinesia in the pediatric patient. Curr Gastroenterol Rep. 2008; 10(3):332-8. DOI: 10.1007/s11894-008-0064-1. View

4.
Li K, Qin W, Ding D, Tomczak N, Geng J, Liu R . Photostable fluorescent organic dots with aggregation-induced emission (AIE dots) for noninvasive long-term cell tracing. Sci Rep. 2013; 3:1150. PMC: 3556677. DOI: 10.1038/srep01150. View

5.
Li M, Hong Y, Wang Z, Chen S, Gao M, Kwok R . Fabrication of chitosan nanoparticles with aggregation-induced emission characteristics and their applications in long-term live cell imaging. Macromol Rapid Commun. 2013; 34(9):767-71. DOI: 10.1002/marc.201200760. View