Implications of Blood Pressure Measurement Technique for Implementation of Systolic Blood Pressure Intervention Trial (SPRINT)

Overview
Date 2017 Feb 5
PMID 28159816
Citations 52
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Cardiovascular morbidity and mortality was reduced by 25% when blood pressure (BP) was targeted to 120 mm Hg systolic compared with 140 mm Hg systolic in Systolic Blood Pressure Intervention Trial (SPRINT); however, BP was measured using a research technique. SPRINT specified 5 minutes of seated rest in a quiet room followed by 3 oscillometric measurements without an observer in the room. The relationship of this research-grade methodology to routine BP measurements is not known.

Methods And Results: Among 275 people with chronic kidney disease who had BP <140/90 mm Hg when they came to the clinic, we measured BP as in SPRINT and recorded BP on the same day without specification of seated rest. Compared with routine measurement, the research-grade systolic BP was 12.7 mm Hg lower with wide limits of agreement (-46.1 to 20.7 mm Hg). Research grade systolic BP was 7.9 mm Hg lower than daytime ambulatory systolic BP and had wide agreement limits (-33.2 to 17.4 mm Hg). Whereas the routine, research-grade, and daytime ambulatory systolic BP were all related to echocardiographic left ventricular hypertrophy, the strength of the relationship between research-grade and daytime ambulatory systolic BP to left ventricular hypertrophy was similar and stronger than the strength of the relationship between routine systolic BP and left ventricular hypertrophy.

Conclusions: Taken together, these results suggest that translation of the SPRINT results will require measurement of BP as performed in that trial. Instead of an algebraic manipulation of routine clinic measurements, the SPRINT methodology of BP measurement would be needed at minimum if implementation of the SPRINT results were to be deployed in the population at large.

Citing Articles

Stakeholder perspectives on barriers and facilitators to hypertension control in urban Haiti: a qualitative study to inform a community-based hypertension management intervention.

St Sauveur R, Sufra R, Pierre M, Inddy J, Jean M, Mourra N BMC Public Health. 2025; 25(1):18.

PMID: 39754124 PMC: 11697642. DOI: 10.1186/s12889-024-20793-2.


Current management of chronic kidney disease in type-2 diabetes-A tiered approach: An overview of the joint Association of British Clinical Diabetologists and UK Kidney Association (ABCD-UKKA) guidelines.

Dasgupta I, Zac-Varghese S, Chaudhry K, McCafferty K, Winocour P, Chowdhury T Diabet Med. 2024; 42(2):e15450.

PMID: 39415639 PMC: 11733655. DOI: 10.1111/dme.15450.


Effectiveness of community-based hypertension management on hypertension in the urban slums of Haiti: A mixed methods study.

St Sauveur R, Sufra R, Pierre M, Rouzier V, Preval F, Exantus S J Clin Hypertens (Greenwich). 2024; 26(10):1133-1144.

PMID: 39150035 PMC: 11466359. DOI: 10.1111/jch.14882.


Spectrum of prevalent cardiovascular diseases in urban Port-au-Prince, Haiti: a population-based cross-sectional study.

Yan L, Sufra R, St Sauveur R, Jean-Pierre M, Apollon A, Malebranche R Lancet Reg Health Am. 2024; 33:100729.

PMID: 38590326 PMC: 11000196. DOI: 10.1016/j.lana.2024.100729.


The diastolic blood pressure J-curve revisited: An update.

Filippone E, Foy A, Naccarelli G Am Heart J Plus. 2024; 12:100065.

PMID: 38559601 PMC: 10978147. DOI: 10.1016/j.ahjo.2021.100065.


References
1.
Cushman W, Evans G, Byington R, Goff Jr D, Grimm Jr R, Cutler J . Effects of intensive blood-pressure control in type 2 diabetes mellitus. N Engl J Med. 2010; 362(17):1575-85. PMC: 4123215. DOI: 10.1056/NEJMoa1001286. View

2.
Myers M, Godwin M, Dawes M, Kiss A, Tobe S, Grant F . Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial. BMJ. 2011; 342:d286. PMC: 3034423. DOI: 10.1136/bmj.d286. View

3.
El Assaad M, Topouchian J, Darne B, Asmar R . Validation of the Omron HEM-907 device for blood pressure measurement. Blood Press Monit. 2002; 7(4):237-41. DOI: 10.1097/00126097-200208000-00006. View

4.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

5.
Devereux R, Alonso D, Lutas E, Gottlieb G, Campo E, Sachs I . Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings. Am J Cardiol. 1986; 57(6):450-8. DOI: 10.1016/0002-9149(86)90771-x. View