» Articles » PMID: 709763

Recommendations Regarding Quantitation in M-mode Echocardiography: Results of a Survey of Echocardiographic Measurements

Overview
Journal Circulation
Date 1978 Dec 1
PMID 709763
Citations 1218
Authors
Affiliations
Soon will be listed here.
Abstract

Four hundred M-mode echocardiographic surveys were distributed to determine interobserver variability in M-mode echocardiographic measurements. This was done with a view toward examining the need and determining the criteria for standardization of measurement. Each survey consisted of five M-mode echocardiograms with a calibration marker, measured by the survey participants anonymously. The echoes were judged of adequate quality for measurement of structures. Seventy-six of the 400 (19%) were returned, allowing comparison of interobserver variability as well as examination of the measurement criteria which were used. Mean measurements and percent uncertainty were derived for each structure for each criterion of measurement. For example, for the aorta, 33% of examiners measured the aorta as an outer/inner or leading edge dimension, and 20% measured it as an outer/outer dimension. The percent uncertainty for the measurement (1.97 SD divided by the mean) showed a mean of 13.8% for the 25 packets of five echoes measured using the former criteria and 24.2% using the latter criteria. For ventricular chamber and cavity measurements, almost one-half of the examiners used the peak of the QRS and one-half of the examiners used the onset of the QRS for determining end-diastole. Estimates of the percent of measurement uncertainty for the septum, posterior wall and left ventricular cavity dimension in this study were 10--25%. They were much higher (40--70%) for the right ventricular cavity and right ventricular anterior wall. The survey shows significant interobserver and interlaboratory variation in measurement when examining the same echoes and indicates a need for ongoing education, quality control and standardization of measurement criteria. Recommendations for new criteria for measurement of M-mode echocardiograms are offered.

Citing Articles

BASELINE CLINICAL CHARACTERISTICS OF CONTEMPORARY ADULT CHRONIC RHEUMATIC HEART DISEASE IN IBADAN, NIGERIA.

Ogah O, Adeyanju A, Iyawe E, Okwunze K, Okeke M, Ugah A Ann Ib Postgrad Med. 2025; 22(2):9-17.

PMID: 40007716 PMC: 11848369.


PERFORMANCE OF THE PEGUERO-LO PRESTI CRITERIA FOR THE DIAGNOSIS OF LEFT VENTRICULAR HYPERTROPHY IN PATIENTS WITH CARDIAC DISEASE IN IBADAN, NIGERIA.

Ogah O, Adebiyi A, Orimolade O, Akinosi T, Aborisade S, Okorie C Ann Ib Postgrad Med. 2025; 22(2):31-37.

PMID: 40007705 PMC: 11848373.


Transcriptome-Wide Insights: Neonatal Lactose Intolerance Promotes Telomere Damage, Senescence, and Cardiomyopathy in Adult Rat Heart.

Anatskaya O, Ponomartsev S, Elmuratov A, Vinogradov A Int J Mol Sci. 2025; 26(4).

PMID: 40004050 PMC: 11855832. DOI: 10.3390/ijms26041584.


Pulmonary Arterial Hypertension-Induced Reproductive Damage: Effects of Combined Physical Training on Testicular and Epididymal Parameters in Rats.

Assis M, Leite L, Guimaraes-Ervilha L, Adao R, Reis E, Natali A Biomedicines. 2025; 13(2).

PMID: 40002823 PMC: 11853577. DOI: 10.3390/biomedicines13020410.


Global Longitudinal Strain score predicts subclinical cardiac involvement of multiple sclerosis patients.

Demir F, Ozbek M, Akil M, Akil E Neurol Sci. 2025; .

PMID: 39954100 DOI: 10.1007/s10072-025-08041-w.