» Articles » PMID: 28076003

Reducing Functional MR Imaging Acquisition Times by Optimizing Workflow

Overview
Journal Radiographics
Specialty Radiology
Date 2017 Jan 12
PMID 28076003
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Functional magnetic resonance (MR) imaging is a complex, specialized examination that is able to noninvasively measure information critical to patient care such as hemispheric language lateralization ( 1 ). Diagnostic functional MR imaging requires extensive patient interaction as well as the coordinated efforts of the entire health care team. We observed in our practice at an academic center that the times to perform functional MR imaging examinations were excessively lengthy, making scheduling of the examination difficult. The purpose of our project was to reduce functional MR imaging acquisition times by increasing the efficiency of our workflow, using specific quality tools to drive improvement of functional MR imaging. We assembled a multidisciplinary team and retrospectively reviewed all functional MR imaging examinations performed at our institution from January 2013 to August 2015. We identified five key drivers: (a) streamlined protocols, (b) consistent patient monitoring, (c) clear visual slides and audio, (d) improved patient understanding, and (e) minimized patient motion. We then implemented four specific interventions over a period of 10 months: (a) eliminating intravenous contrast medium, (b) reducing repeated language paradigms, (c) updating technologist and physician checklists, and (d) updating visual slides and audio. Our mean functional MR imaging acquisition time was reduced from 76.3 to 53.2 minutes, while our functional MR imaging examinations remained of diagnostic quality. As a result, we reduced our routine scheduling time for functional MR imaging from 2 hours to 1 hour, improving patient comfort and satisfaction as well as saving time for additional potential MR imaging acquisitions. Our efforts to optimize functional MR imaging workflow constitute a practice quality improvement project that is beneficial for patient care and can be applied broadly to other functional MR imaging practices. RSNA, 2017.

Citing Articles

Impact of Deep Learning Image Reconstruction Methods on MRI Throughput.

Yang A, Finkelstein M, Koo C, Doshi A Radiol Artif Intell. 2024; 6(3):e230181.

PMID: 38506618 PMC: 11140511. DOI: 10.1148/ryai.230181.


Simulation and evaluation of increased imaging service capacity at the MRI department using reduced coil-setting times.

Sun Y, Wu H, Guo W, Ou Y, Yao M, Lee L PLoS One. 2023; 18(7):e0288546.

PMID: 37498942 PMC: 10374078. DOI: 10.1371/journal.pone.0288546.


Factors affecting MRI scanner efficiency in an academic center.

Smereka P, Weng J, Block K, Chandarana H Abdom Radiol (NY). 2022; 47(11):3909-3915.

PMID: 35918543 PMC: 10321367. DOI: 10.1007/s00261-022-03599-x.


Performance of single-use syringe versus multi-use MR contrast injectors: a prospective comparative study.

Struik F, Futterer J, Prokop W Sci Rep. 2020; 10(1):3946.

PMID: 32127584 PMC: 7054519. DOI: 10.1038/s41598-020-60697-w.