Computed Tomography and Patient Risk: Facts, Perceptions and Uncertainties

Overview
Journal World J Radiol
Specialty Radiology
Date 2017 Jan 11
PMID 28070242
Citations 91
Authors
Affiliations
Soon will be listed here.
Abstract

Since its introduction in the 1970s, computed tomography (CT) has revolutionized diagnostic decision-making. One of the major concerns associated with the widespread use of CT is the associated increased radiation exposure incurred by patients. The link between ionizing radiation and the subsequent development of neoplasia has been largely based on extrapolating data from studies of survivors of the atomic bombs dropped in Japan in 1945 and on assessments of the increased relative risk of neoplasia in those occupationally exposed to radiation within the nuclear industry. However, the association between exposure to low-dose radiation from diagnostic imaging examinations and oncogenesis remains unclear. With improved technology, significant advances have already been achieved with regards to radiation dose reduction. There are several dose optimization strategies available that may be readily employed including omitting unnecessary images at the ends of acquired series, minimizing the number of phases acquired, and the use of automated exposure control as opposed to fixed tube current techniques. In addition, new image reconstruction techniques that reduce radiation dose have been developed in recent years with promising results. These techniques use iterative reconstruction algorithms to attain diagnostic quality images with reduced image noise at lower radiation doses.

Citing Articles

Quality of referrals and adherence to guidelines for adult patients with minimal to moderate head injuries in a selection of Norwegian hospitals.

Kjelle E, Brandsaeter I, Lauritzen P, Andersen E, Porthun J, Hofmann B Eur J Trauma Emerg Surg. 2025; 51(1):62.

PMID: 39856393 PMC: 11762200. DOI: 10.1007/s00068-024-02680-y.


Artificial Intelligence in Pancreatic Intraductal Papillary Mucinous Neoplasm Imaging: A Systematic Review.

Qadir M, Baril J, Yip-Schneider M, Schonlau D, Tran T, Schmidt C medRxiv. 2025; .

PMID: 39830259 PMC: 11741484. DOI: 10.1101/2025.01.08.25320130.


Diagnostic value of CT scans in pediatric patients with acute non-traumatic altered mental status: a systematic review and meta-analysis.

Alsabri M, Ayyad M, Aziz M, Zaazouee M, Elshanbary A, Shafique M Eur J Pediatr. 2025; 184(2):136.

PMID: 39812876 PMC: 11735565. DOI: 10.1007/s00431-024-05943-3.


Role of high-resolution magnetic resonance imaging in preoperative tumor-node-metastasis staging evaluation of esophageal cancer: a narrative review.

Lin Y, Lin Q, Huang L, Wang J, Ma R, Liu J Quant Imaging Med Surg. 2024; 14(12):9589-9599.

PMID: 39698700 PMC: 11652015. DOI: 10.21037/qims-24-34.


Artificial intelligence applied to coronary artery calcium scans (AI-CAC) significantly improves cardiovascular events prediction.

Naghavi M, Reeves A, Atlas K, Zhang C, Atlas T, Henschke C NPJ Digit Med. 2024; 7(1):309.

PMID: 39501071 PMC: 11538462. DOI: 10.1038/s41746-024-01308-0.


References
1.
OSullivan J, OConnor O, ORegan K, Clarke B, Burgoyne L, Ryan M . An assessment of medical students' awareness of radiation exposures associated with diagnostic imaging investigations. Insights Imaging. 2012; 1(2):86-92. PMC: 3259343. DOI: 10.1007/s13244-010-0009-8. View

2.
Schauer D, Linton O . National Council on Radiation Protection and Measurements report shows substantial medical exposure increase. Radiology. 2009; 253(2):293-6. DOI: 10.1148/radiol.2532090494. View

3.
Baumann B, Chen E, Mills A, Glaspey L, Thompson N, Jones M . Patient perceptions of computed tomographic imaging and their understanding of radiation risk and exposure. Ann Emerg Med. 2010; 58(1):1-7.e2. DOI: 10.1016/j.annemergmed.2010.10.018. View

4.
Huang W, Muo C, Lin C, Jen Y, Yang M, Lin J . Paediatric head CT scan and subsequent risk of malignancy and benign brain tumour: a nation-wide population-based cohort study. Br J Cancer. 2014; 110(9):2354-60. PMC: 4007220. DOI: 10.1038/bjc.2014.103. View

5.
Silva A, Lawder H, Hara A, Kujak J, Pavlicek W . Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol. 2009; 194(1):191-9. DOI: 10.2214/AJR.09.2953. View