» Articles » PMID: 2802566

Performance Characteristics of Two Bioassays and High-performance Liquid Chromatography for Determination of Flucytosine in Serum

Overview
Specialty Pharmacology
Date 1989 Aug 1
PMID 2802566
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

We compared the accuracy and precision of two microbiological methods and one high-pressure liquid chromatography (HPLC) procedure used to measure the concentrations of flucytosine in serum. On the basis of an analysis of six standards, all methods were judged reliable within acceptable limits for clinical use. With the biological methods, a slight loss of linearity was observed in the 75- to 100-micrograms/ml range. Compared with the bioassays, the HPLC method did not present linearity problems and was more precise and accurate in the critical zone of 100 micrograms/ml. On average, results obtained with patient sera containing 50 to 100 micrograms of flucytosine per ml were 10.6% higher with the HPLC method than with the bioassays. Standards for the biological assays may be prepared in serum or water.

Citing Articles

Preferential degradation of phenolic lignin units by two white rot fungi.

Camarero S, Galletti G, Martinez A Appl Environ Microbiol. 1994; 60(12):4509-16.

PMID: 7811086 PMC: 202012. DOI: 10.1128/aem.60.12.4509-4516.1994.

References
1.
Richardson R . Rapid fluorimetric determination of 5-fluorocytosine in serum. Clin Chim Acta. 1975; 63(2):109-14. DOI: 10.1016/0009-8981(75)90152-7. View

2.
Wee S, Anhalt J . Gas chromatographic determination of 5-fluorocytosine: a modified extraction method. Antimicrob Agents Chemother. 1977; 11(5):914-5. PMC: 352097. DOI: 10.1128/AAC.11.5.914. View

3.
Miners J, Foenander T, Birkett D . Liquid-chromatographic determination of 5-fluorocytosine. Clin Chem. 1980; 26(1):117-9. View

4.
Warnock D, Turner A . High performance liquid chromatographic determination of 5-fluorocytosine in human serum. J Antimicrob Chemother. 1981; 7(4):363-9. DOI: 10.1093/jac/7.4.363. View

5.
Roselle G, Warth P . Determination of serum 5-fluorocytosine concentrations in the presence of ketoconazole. J Antimicrob Chemother. 1983; 12(2):189-92. DOI: 10.1093/jac/12.2.189. View