» Articles » PMID: 28013392

The Clinical Depth of Field Achievable with Trifocal and Monofocal Intraocular Lenses: Theoretical Considerations and Proof of Concept Clinical Results

Overview
Specialty Ophthalmology
Date 2016 Dec 26
PMID 28013392
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: To estimate the depth of field (DOF) achievable with multi-and monofocal intraocular lenses (IOLs) and compare with actual measurements of DOF in cases implanted with a trifocal IOL and biconvex monofocal IOL METHODS: I) Computer simulations were produced to describe the relationship between DOF, pupil size, preoperative ametropia, and retinal blur tolerance limit for a model eye implanted with either multi- or monofocal IOLs. II) Monocular DOF and pupil size were measured under distance viewing conditions between 3 and 6 months postoperative following uneventful cataract surgery. Cases were implanted with either i) trifocal aspheric IOL (n = 36), or ii) biconvex aspheric monofocal IOL (n = 26). DOF was also measured at 0.33 m in cases implanted with i).

Results: Simulations revealed significant associations between DOF, pupil size, and retinal blur tolerance limit. The mean (±SD) DOF & pupil sizes were at distance for i)  above 2.59D (0.68) & 3.54 mm (0.377), and for ii) above 1.67D (0.51) & 2.90 mm (0.351), and for i) above 3.16D (0.46) at near. The difference between groups were significant for DOF and pupil size at distance (p < 0.001). DOF was significantly greater at near compared with distance in i) above (p < 0.001). For a pupil size of 3 mm, the simulations produce similar DOF values when the tolerance limit of retinal blur is 10 μ.

Conclusions: The DOF was significantly better after implanting the trifocal IOL compared with the monofocal IOL, and DOF is increased under near viewing conditions. The clinical results are similar to calculated DOF values when the tolerance limit of retinal blur is 10 μ.

Citing Articles

Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses - A Retrospective Comparative Study of Mini Well Ready and Symfony.

Nowik K, Nowik K, Kanclerz P, Szaflik J Clin Ophthalmol. 2022; 16:1613-1621.

PMID: 35651536 PMC: 9150758. DOI: 10.2147/OPTH.S341698.


Depth of field and visual performance after implantation of a new hydrophobic trifocal intraocular lens.

Palomino-Bautista C, Cervino A, Cuina-Sardina R, Carmona-Gonzalez D, Castillo-Gomez A, Sanchez-Jean R BMC Ophthalmol. 2022; 22(1):240.

PMID: 35642049 PMC: 9153098. DOI: 10.1186/s12886-022-02462-3.


Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS.

Palomino-Bautista C, Sanchez-Jean R, Carmona-Gonzalez D, Pinero D, Molina-Martin A Sci Rep. 2021; 11(1):12081.

PMID: 34103624 PMC: 8187633. DOI: 10.1038/s41598-021-91654-w.


Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses.

Palomino-Bautista C, Sanchez-Jean R, Carmona-Gonzalez D, Pinero D, Molina-Martin A Int Ophthalmol. 2019; 40(2):351-359.

PMID: 31583551 DOI: 10.1007/s10792-019-01186-6.

References
1.
Knorz M, Claessens D, SCHAEFER R, Seiberth V, Liesenhoff H . Evaluation of contrast acuity and defocus curve in bifocal and monofocal intraocular lenses. J Cataract Refract Surg. 1993; 19(4):513-23. DOI: 10.1016/s0886-3350(13)80616-5. View

2.
Gupta N, Naroo S, Wolffsohn J . Is randomisation necessary for measuring defocus curves in pre-presbyopes?. Cont Lens Anterior Eye. 2007; 30(2):119-24. DOI: 10.1016/j.clae.2007.02.005. View

3.
Post Jr C . Comparison of depth of focus and low-contrast acuities for monofocal versus multifocal intraocular lens patients at 1 year. Ophthalmology. 1992; 99(11):1658-63; discussion 1663-4. DOI: 10.1016/s0161-6420(92)31735-x. View

4.
Benard Y, Lopez-Gil N, Legras R . Optimizing the subjective depth-of-focus with combinations of fourth- and sixth-order spherical aberration. Vision Res. 2011; 51(23-24):2471-7. DOI: 10.1016/j.visres.2011.10.003. View

5.
Kamlesh , Dadeya S, Kaushik S . Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lens. Can J Ophthalmol. 2001; 36(4):197-201. DOI: 10.1016/s0008-4182(01)80040-5. View