» Articles » PMID: 27685323

Antibody Labeling with Fluorescent Dyes Using Magnetic Protein A and Protein G Beads

Overview
Journal J Vis Exp
Date 2016 Sep 30
PMID 27685323
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Antibodies labeled with small molecules like fluorescent dyes, cytotoxic drugs, and radioactive tracers are essential tools in biomedical research, immunodiagnostics and more recently as therapeutic agents. Traditional methods for labeling antibodies with small molecules require purified antibodies at relatively high concentration, involve multiple dialysis steps and have limited throughput. However, several applications, including the field of Antibody Drug Conjugates (ADCs), will benefit from new methods that will allow labeling of antibodies directly from cell media. Such methods may allow antibodies to be screened in biologically relevant assays, for example, the receptor-mediated antibody internalization assay in the case of ADCs. Here, we describe a method (on-bead method) that enables labeling of small amounts of antibodies directly from cell media. This approach utilizes high capacity magnetic Protein A and Protein G affinity beads to capture antibodies from the cell media followed by labeling with small molecules using either amine or thiol chemistry and subsequent elution of the labeled antibodies. Taking fluorescent dyes as surrogates for small molecules, we demonstrate the on-bead labeling of three different mouse antibodies directly from cell media using both amine and thiol labeling chemistry. The high binding affinity of antibodies to Protein A and Protein G ensures high recoveries as well as high purity of the labeled antibodies. In addition, use of magnetic beads allows multiple samples to be handled manually, thereby significantly improving labeling throughput.

Citing Articles

New Red-Shifted 4-Styrylcoumarin Derivatives as Potential Fluorescent Labels for Biomolecules.

Eustaquio R, Ramalho J, Caldeira A, Pereira A Molecules. 2022; 27(5).

PMID: 35268562 PMC: 8912076. DOI: 10.3390/molecules27051461.

References
1.
Kraeber-Bodere F, Bodet-Milin C, Rousseau C, Eugene T, Pallardy A, Frampas E . Radioimmunoconjugates for the treatment of cancer. Semin Oncol. 2014; 41(5):613-22. DOI: 10.1053/j.seminoncol.2014.07.004. View

2.
Day J, Marquez B, Beck H, Aweda T, Gawande P, Meares C . Chemically modified antibodies as diagnostic imaging agents. Curr Opin Chem Biol. 2010; 14(6):803-9. PMC: 3010408. DOI: 10.1016/j.cbpa.2010.09.015. View

3.
Cunningham R . Overview of flow cytometry and fluorescent probes for flow cytometry. Methods Mol Biol. 2009; 588:319-26. DOI: 10.1007/978-1-59745-324-0_31. View

4.
Liao-Chan S, Daine-Matsuoka B, Heald N, Wong T, Lin T, Cai A . Quantitative assessment of antibody internalization with novel monoclonal antibodies against Alexa fluorophores. PLoS One. 2015; 10(4):e0124708. PMC: 4403856. DOI: 10.1371/journal.pone.0124708. View

5.
Lundberg E, Sundberg M, Graslund T, Uhlen M, Andersson Svahn H . A novel method for reproducible fluorescent labeling of small amounts of antibodies on solid phase. J Immunol Methods. 2007; 322(1-2):40-9. DOI: 10.1016/j.jim.2007.01.023. View