» Articles » PMID: 27679550

Interdisciplinary Consensus Statement on Indication and Application of a Hydrogel Spacer for Prostate Radiotherapy Based on Experience in More Than 250 Patients

Overview
Journal Radiol Oncol
Publisher Sciendo
Specialties Oncology
Radiology
Date 2016 Sep 29
PMID 27679550
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The aim of the study was to reach a consensus on indication and application of a hydrogel spacer based on multicentre experience and give new users important information to shorten the learning curve for this innovative technique.

Methods: The interdisciplinary meeting was attended by radiation oncologists and urologists, each with experience of 23 - 138 hydrogel injections (SpaceOAR®) in prostate cancer patients before dose-escalated radiotherapy. User experience was discussed and questions were defined to comprise practical information relevant for successful hydrogel injection and treatment. Answers to the defined key questions were generated. Hydrogel-associated side effects were collected to estimate the percentage, treatment and prognosis of potential risks.

Results: The main indication for hydrogel application was dose-escalated radiotherapy for histologically confirmed low or intermediate risk prostate cancer. It was not recommended in locally advanced prostate cancer. The injection or implantation was performed under transrectal ultrasound guidance via the transperineal approach after prior hydrodissection. The rate of injection-related G2-toxicity was 2% (n = 5) in a total of 258 hydrogel applications. The most frequent complication (n = 4) was rectal wall penetration, diagnosed at different intervals after hydrogel injection and treated conservatively.

Conclusions: A consensus was reached on the application of a hydrogel spacer. Current experience demonstrated feasibility, which could promote initiation of this method in more centres to reduce radiation-related gastrointestinal toxicity of dose-escalated IGRT. However, a very low rate of a potential serious adverse event could not be excluded. Therefore, the application should carefully be discussed with the patient and be balanced against potential benefits.

Citing Articles

XIOSIS: An X-Ray-Based Intra-Operative Image-Guided Platform for Oncology Smart Material Delivery.

Hooshangnejad H, China D, Huang Y, Zbijewski W, Uneri A, McNutt T IEEE Trans Med Imaging. 2024; 43(9):3176-3187.

PMID: 38602853 PMC: 11418373. DOI: 10.1109/TMI.2024.3387830.


Application of Hydrogel Spacer SpaceOAR Vue for Prostate Radiotherapy.

Hadigal S, Gupta A Tomography. 2022; 8(6):2648-2661.

PMID: 36412680 PMC: 9680261. DOI: 10.3390/tomography8060221.


Comprehensive review of the use of hydrogel spacers prior to radiation therapy for prostate cancer.

Harvey M, Ong W, Chao M, Udovicich C, McBride S, Bolton D BJU Int. 2022; 131(3):280-287.

PMID: 35689413 PMC: 9734283. DOI: 10.1111/bju.15821.


Finite Element-Based Personalized Simulation of Duodenal Hydrogel Spacer: Spacer Location Dependent Duodenal Sparing and a Decision Support System for Spacer-Enabled Pancreatic Cancer Radiation Therapy.

Hooshangnejad H, Youssefian S, Narang A, Shin E, Rao A, Han-Oh S Front Oncol. 2022; 12:833231.

PMID: 35402281 PMC: 8987290. DOI: 10.3389/fonc.2022.833231.


Demonstrating the benefits of corrective intraoperative feedback in improving the quality of duodenal hydrogel spacer placement.

Hooshangnejad H, Han-Oh S, Shin E, Narang A, Rao A, Lee J Med Phys. 2022; 49(7):4794-4803.

PMID: 35394064 PMC: 9540875. DOI: 10.1002/mp.15665.


References
1.
Nguyen P, Devlin P, Beard C, Orio 3rd P, OLeary M, Wolfsberger L . High-dose-rate brachytherapy for prostate cancer in a previously radiated patient with polyethylene glycol hydrogel spacing to reduce rectal dose: case report and review of the literature. Brachytherapy. 2012; 12(1):77-83. DOI: 10.1016/j.brachy.2012.03.005. View

2.
Arcangeli S, Agolli L, Donato V . Retreatment for prostate cancer with stereotactic body radiation therapy (SBRT): Feasible or foolhardy?. Rep Pract Oncol Radiother. 2015; 20(6):425-9. PMC: 4661353. DOI: 10.1016/j.rpor.2014.08.001. View

3.
Song D, Herfarth K, Uhl M, Eble M, Pinkawa M, van Triest B . A multi-institutional clinical trial of rectal dose reduction via injected polyethylene-glycol hydrogel during intensity modulated radiation therapy for prostate cancer: analysis of dosimetric outcomes. Int J Radiat Oncol Biol Phys. 2013; 87(1):81-7. PMC: 3737267. DOI: 10.1016/j.ijrobp.2012.12.019. View

4.
Ng M, Brown E, Williams A, Chao M, Lawrentschuk N, Chee R . Fiducial markers and spacers in prostate radiotherapy: current applications. BJU Int. 2014; 113 Suppl 2:13-20. DOI: 10.1111/bju.12624. View

5.
Hatiboglu G, Pinkawa M, Vallee J, Hadaschik B, Hohenfellner M . Application technique: placement of a prostate-rectum spacer in men undergoing prostate radiation therapy. BJU Int. 2012; 110(11 Pt B):E647-52. DOI: 10.1111/j.1464-410X.2012.11373.x. View