Abstract

Background: Since the 2003 severe acute respiratory syndrome epidemic, scientific exploration of infection control is no longer restricted to microbiologists or medical scientists. Many studies have reported on the release, transport, and exposure of expiratory droplets because of respiratory activities. This review focuses on the airborne spread of infectious agents from mucus to mucus in the indoor environment and their spread as governed by airflows in the respiratory system, around people, and in buildings at different transport stages.

Methods: We critically review the literature on the release of respiratory droplets, their transport and dispersion in the indoor environment, and the ultimate exposure of a susceptible host, as influenced by airflows.

Results: These droplets or droplet nuclei are transported by expired airflows, which are sometimes affected by the human body plume and use of a face mask, as well as room airflow. Room airflow is affected by human activities such as walking and door opening, and some droplets are eventually captured by a susceptible individual because of his or her inspired flows; such exposure can eventually lead to long-range spread of airborne pathogens. Direct exposure to the expired fine droplets or droplet nuclei results in short-range airborne transmission. Deposition of droplets and direct personal exposure to expired large droplets can lead to the fomite route and the droplet-borne route, respectively.

Conclusions: We have shown the opportunities for infection control at different stages of the spread. We propose that the short-range airborne route may be important in close contact, and its control may be achieved by face masks for the source patients and use of personalized ventilation. Our discussion of the effect of thermal stratification and expiratory delivery of droplets leads to the suggestion that displacement ventilation may not be applicable to hospital rooms where respiratory infection is a concern.

Citing Articles

Open-set deep learning-enabled single-cell Raman spectroscopy for rapid identification of airborne pathogens in real-world environments.

Zhu L, Yang Y, Xu F, Lu X, Shuai M, An Z Sci Adv. 2025; 11(2):eadp7991.

PMID: 39772685 PMC: 11708874. DOI: 10.1126/sciadv.adp7991.


Resuspension and Dissemination of MS2 Virus from Flooring After Human Activities in Built Environment: Impact of Dust Particles.

Boone S, Ijaz M, McKinney J, Gerba C Microorganisms. 2025; 12(12.

PMID: 39770767 PMC: 11678224. DOI: 10.3390/microorganisms12122564.


Recent Developments in Aptamer-Based Sensors for Diagnostics.

Sheraz M, Sun X, Wang Y, Chen J, Sun L Sensors (Basel). 2024; 24(23).

PMID: 39685966 PMC: 11644826. DOI: 10.3390/s24237432.


Rapid virucidal activity of an air sanitizer against aerosolized MS2 and Phi6 phage surrogates for non-enveloped and enveloped vertebrate viruses, including SARS-CoV-2.

Ijaz M, Zargar B, Nims R, McKinney J, Sattar S Appl Environ Microbiol. 2024; 91(1):e0142624.

PMID: 39641606 PMC: 11784435. DOI: 10.1128/aem.01426-24.


The Determination of the Rapid and Effective Activity of an Air Sanitizer against Aerosolized Bacteria Using a Room-Sized Aerobiology Chamber.

Zargar B, Ijaz M, Kevek A, Miller M, McKinney J, Sattar S Microorganisms. 2024; 12(10).

PMID: 39458382 PMC: 11510681. DOI: 10.3390/microorganisms12102072.


References
1.
Tellier R . Review of aerosol transmission of influenza A virus. Emerg Infect Dis. 2007; 12(11):1657-62. PMC: 3372341. DOI: 10.3201/eid1211.060426. View

2.
Tellier R . Aerosol transmission of influenza A virus: a review of new studies. J R Soc Interface. 2009; 6 Suppl 6:S783-90. PMC: 2843947. DOI: 10.1098/rsif.2009.0302.focus. View

3.
Tang J . The effect of environmental parameters on the survival of airborne infectious agents. J R Soc Interface. 2009; 6 Suppl 6:S737-46. PMC: 2843949. DOI: 10.1098/rsif.2009.0227.focus. View

4.
Holmgren H, Ljungstrom E . Influence of film dimensions on film droplet formation. J Aerosol Med Pulm Drug Deliv. 2011; 25(1):47-53. DOI: 10.1089/jamp.2011.0892. View

5.
Edwards D, Man J, Brand P, Katstra J, Sommerer K, Stone H . Inhaling to mitigate exhaled bioaerosols. Proc Natl Acad Sci U S A. 2004; 101(50):17383-8. PMC: 536048. DOI: 10.1073/pnas.0408159101. View