In Vivo Retinal and Choroidal Hypoxia Imaging Using a Novel Activatable Hypoxia-selective Near-infrared Fluorescent Probe
Overview
Authors
Affiliations
Purpose: Retinal hypoxia plays a crucial role in ocular neovascular diseases, such as diabetic retinopathy, retinopathy of prematurity, and retinal vascular occlusion. Fluorescein angiography is useful for identifying the hypoxia extent by detecting non-perfusion areas or neovascularization, but its ability to detect early stages of hypoxia is limited. Recently, in vivo fluorescent probes for detecting hypoxia have been developed; however, these have not been extensively applied in ophthalmology. We evaluated whether a novel donor-excited photo-induced electron transfer (d-PeT) system based on an activatable hypoxia-selective near-infrared fluorescent (NIRF) probe (GPU-327) responds to both mild and severe hypoxia in various ocular ischemic diseases animal models.
Methods: The ocular fundus examination offers unique opportunities for direct observation of the retina through the transparent cornea and lens. After injection of GPU-327 in various ocular hypoxic diseases of mouse and rabbit models, NIRF imaging in the ocular fundus can be performed noninvasively and easily by using commercially available fundus cameras. To investigate the safety of GPU-327, electroretinograms were also recorded after GPU-327 and PBS injection.
Result: Fluorescence of GPU-327 increased under mild hypoxic conditions in vitro. GPU-327 also yielded excellent signal-to-noise ratio without washing out in vivo experiments. By using near-infrared region, GPU-327 enables imaging of deeper ischemia, such as choroidal circulation. Additionally, from an electroretinogram, GPU-327 did not cause neurotoxicity.
Conclusions: GPU-327 identified hypoxic area both in vivo and in vitro.
Development of a near-infrared fluorescent probe for the selective detection of severe hypoxia.
Kasai T, Fujita K, Komatsu T, Ueno T, Kojima R, Hanaoka K RSC Chem Biol. 2025; 6(3):449-456.
PMID: 39911856 PMC: 11791654. DOI: 10.1039/d4cb00243a.
Imaging Hypoxia to Predict Primary Neuronal Cell Damage in Branch Retinal Artery Occlusion.
Jamal S, Dieckmann B, McCollum G, Penn J, Jayagopal A, Imam Uddin M Microcirculation. 2024; 31(7):e12883.
PMID: 39213162 PMC: 11471370. DOI: 10.1111/micc.12883.
Animal Models Used to Simulate Retinal Artery Occlusion: A Comprehensive Review.
Vestergaard N, Cehofski L, Honore B, Aasbjerg K, Vorum H Transl Vis Sci Technol. 2019; 8(4):23.
PMID: 31440422 PMC: 6701503. DOI: 10.1167/tvst.8.4.23.
Luminescent Probe Based Techniques for Hypoxia Imaging.
Sandhu S, Kydd L, Jaworski J J Nanomed Res. 2018; 6(3).
PMID: 30417104 PMC: 6223636. DOI: 10.15406/jnmr.2017.06.00160.
Uddin M, Jayagopal A, McCollum G, Yang R, Penn J Invest Ophthalmol Vis Sci. 2017; 58(9):3818-3824.
PMID: 28750413 PMC: 5531786. DOI: 10.1167/iovs.16-21187.