A "screened" Electrostatic Ion Trap for Enhanced Mass Resolution, Mass Accuracy, Reproducibility, and Upper Mass Limit in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Overview
Journal Anal Chem
Specialty Chemistry
Date 1989 Jun 1
PMID 2757208
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Until now, it was thought that the optimal static electromagnetic ion trap for Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry should be designed to produce a quadrupolar electrical potential, for which the ion cyclotron frequency is independent of the ion's preexcitation location within the trap. However, a quadrupolar potential results in a transverse (to the magnetic field) electric field that increases linearly with distance from the center of the trap. That radially linear electric field shifts the observed ICR frequency, increases the ICR orbital radius, and ultimately limits the highest mass-to-charge ratio ion that can be contained within the trap. In this paper, we propose a new static electromagnetic ion "trap" in which grounded screens placed just inside the usual "trapping" plates produce a good approximation to a "particle-in-a-box" potential (rather than the quadrupolar "harmonic oscillator" potential). SIMION calculations confirm that the electric potential of the screened trap is near zero almost everywhere within the trap. For our screened orthorhombic (2.5 in. X 2 in. X 2 in.) trap, the experimental ICR frequency shift due to trapping voltage is reduced by a factor of approximately 100, and the experimental variation of ICR frequency with ICR radius is reduced by a factor of approximately 10 compared to a conventional (unscreened) 2-in. cubic ion trap.(ABSTRACT TRUNCATED AT 250 WORDS)

Citing Articles

Evaluation of major historical ICR cell designs using electric field simulations.

Nikolaev E, Lioznov A Mass Spectrom Rev. 2020; 41(2):262-283.

PMID: 33238049 PMC: 9292346. DOI: 10.1002/mas.21671.


Numerical Simulations and the Design of Magnetic Field-Enhanced Electron Impact Ion Source with Hollow Cylinder Structure.

Qi G, Tian D, Gao G, Liu G, Qiu C, Long T J Anal Methods Chem. 2020; 2020:2809485.

PMID: 32399307 PMC: 7204179. DOI: 10.1155/2020/2809485.


High resolution and tandem fourier-transform mass spectrometry with californium-252 plasma desorption.

Williams E, McLafferty F J Am Soc Mass Spectrom. 2013; 1(6):427-30.

PMID: 24248976 DOI: 10.1016/1044-0305(90)85025-H.


Direct observation of trapping motion in elongated fourier-transform mass spectrometry trapped ion cells.

Hofstadler S, Laude D J Am Soc Mass Spectrom. 2013; 1(5):351-60.

PMID: 24248896 DOI: 10.1016/1044-0305(90)85014-D.


Efficiency of collisionally-activated dissociation and 193-nm photodissociation of peptide ions in fourier transform mass spectrometry.

Williams E, Furlong J, McLafferty F J Am Soc Mass Spectrom. 2013; 1(4):288-94.

PMID: 24248821 DOI: 10.1016/1044-0305(90)85003-5.