» Articles » PMID: 27515140

Disinfection and Sterilization in Health Care Facilities: An Overview and Current Issues

Overview
Date 2016 Aug 13
PMID 27515140
Citations 43
Authors
Affiliations
Soon will be listed here.
Abstract

When properly used, disinfection and sterilization can ensure the safe use of invasive and noninvasive medical devices. The method of disinfection and sterilization depends on the intended use of the medical device: critical items (contact sterile tissue) must be sterilized before use; semicritical items (contact mucous membranes or nonintact skin) must be high-level disinfected; and noncritical items (contact intact skin) should receive low-level disinfection. Cleaning should always precede high-level disinfection and sterilization. Current disinfection and sterilization guidelines must be strictly followed.

Citing Articles

Effects of beta and gamma radiation sterilization on growth factor-loaded nanoparticles: an innovative approach for osteoarticular disorders treatment.

Ordoyo-Pascual J, Ruiz-Alonso S, Gallego I, Saenz-Del-Burgo L, Pedraz J Drug Deliv Transl Res. 2025; .

PMID: 40069530 DOI: 10.1007/s13346-025-01829-5.


A comparative assessment of contamination rates in gastrointestinal endoscope reprocessing: sterilization versus high-level disinfection.

Chantarojanasiri T, Rungrueangmaitree R, Thongsri S, Jampa-Ngern U, Ratanachu-Ek T DEN Open. 2025; 5(1):e70093.

PMID: 40066176 PMC: 11891260. DOI: 10.1002/deo2.70093.


Efficacy of Antimicrobial Dry Fog in Improving the Environmental Microbial Burden in an Inpatient Ward.

Jalali Y, Kolosova A, Dzupa K, Pavlovic P, Jalali M, Racek P Antibiotics (Basel). 2025; 13(12.

PMID: 39766577 PMC: 11672662. DOI: 10.3390/antibiotics13121187.


Comparison of different disinfection protocols against contamination of ceramic surfaces with biofilm.

Piletic K, Meznaric S, Kerzic E, Oder M, Gobin I Arh Hig Rada Toksikol. 2024; 75(4):289-296.

PMID: 39718087 PMC: 11667714. DOI: 10.2478/aiht-2024-75-3920.


UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces.

Yeoh L, Cogar L, Barak M, Tan L, Spargo G, Burdach J PLoS One. 2024; 19(10):e0312931.

PMID: 39476107 PMC: 11524522. DOI: 10.1371/journal.pone.0312931.


References
1.
Shaughnessy M, Micielli R, DePestel D, Arndt J, Strachan C, Welch K . Evaluation of hospital room assignment and acquisition of Clostridium difficile infection. Infect Control Hosp Epidemiol. 2011; 32(3):201-6. DOI: 10.1086/658669. View

2.
Cook B, Cutts T, Nikiforuk A, Poliquin P, Court D, Strong J . Evaluating environmental persistence and disinfection of the Ebola virus Makona variant. Viruses. 2015; 7(4):1975-86. PMC: 4411685. DOI: 10.3390/v7041975. View

3.
Hota B, Blom D, Lyle E, Weinstein R, Hayden M . Interventional evaluation of environmental contamination by vancomycin-resistant enterococci: failure of personnel, product, or procedure?. J Hosp Infect. 2008; 71(2):123-31. DOI: 10.1016/j.jhin.2008.10.030. View

4.
Eckstein B, Adams D, Eckstein E, Rao A, Sethi A, Yadavalli G . Reduction of Clostridium Difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods. BMC Infect Dis. 2007; 7:61. PMC: 1906786. DOI: 10.1186/1471-2334-7-61. View

5.
Williams D, Dingley J, Jones C, Berry N . Contamination of laryngoscope handles. J Hosp Infect. 2010; 74(2):123-8. DOI: 10.1016/j.jhin.2009.09.015. View