» Articles » PMID: 27488830

Indirect Calorimetry in Mechanically Ventilated Patients: A Prospective, Randomized, Clinical Validation of 2 Devices Against a Gold Standard

Overview
Publisher Wiley
Date 2016 Aug 5
PMID 27488830
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Aims: The 2 currently available indirect calorimeters, CCM Express Indirect Calorimeter (MedGraphics, St Paul, MN) and Quark RMR ICU Indirect Calorimeter (COSMED, Rome, Italy), have not been validated against a gold standard in mechanically ventilated patients. Our aim was to do so using a gold-standard, modified Tissot bell-spirometer method in mechanically ventilated patients who were hemodynamically, respiratory, and metabolically stable.

Methods: We studied 30 patients undergoing general anesthesia and major gynecological surgery. We measured oxygen consumption ([Formula: see text]O) and resting energy expenditure (REE) in a randomized, sequential, crossover design with double determination of each device.

Results: Compared with the modified Tissot bell-spirometer, the CCM Express Indirect Calorimeter demonstrated a mean Δ-REE of +361 kcal/d, corresponding to a 31% overestimation of energy requirements. Bland-Altman analysis for REE showed a mean (SD) bias of 384 (124) with limits of agreement 142-627 kcal/d. QUARK RMR ICU demonstrated a mean Δ-REE of 81 kcal/d, corresponding to a 7% overestimation of energy requirements. Bland-Altman plot analysis showed a mean (SD) bias of 77 (167) with limits of agreement -249 to 404 kcal/d.

Conclusions: The QUARK RMR ICU Indirect Calorimeter compared better with the gold standard for values of [Formula: see text]O and REE than did the CCM Express Indirect Calorimeter in mechanically ventilated patients who were circulatory and respiratory stable. Both indirect calorimeters had low precision.

Citing Articles

Perioperative estimations of oxygen consumption from LiDCO™plus-derived cardiac output and Ca-cvO2 difference: Relationship with measurements by indirect calorimetry in elderly patients undergoing major abdominal surgery.

Jakobsson J, Noren C, Hagel E, Backheden M, Kalman S, Bartha E PLoS One. 2024; 19(7):e0272239.

PMID: 39052563 PMC: 11271938. DOI: 10.1371/journal.pone.0272239.


Energy expenditure in COVID-19 mechanically ventilated patients: A comparison of three methods of energy estimation.

Saseedharan S, Chada R, Kadam V, Chiluka A, Nagalla B JPEN J Parenter Enteral Nutr. 2022; 46(8):1875-1882.

PMID: 35526145 PMC: 9348140. DOI: 10.1002/jpen.2393.


Fluvastatin Reduces Glucose Tolerance in Healthy Young Individuals Independently of Cold Induced BAT Activity.

Felder M, Maushart C, Gashi G, Senn J, Becker A, Muller J Front Endocrinol (Lausanne). 2021; 12:765807.

PMID: 34858338 PMC: 8631514. DOI: 10.3389/fendo.2021.765807.


Early goal-directed nutrition versus standard of care in adult intensive care patients: the single-centre, randomised, outcome assessor-blinded EAT-ICU trial.

Allingstrup M, Kondrup J, Wiis J, Claudius C, Pedersen U, Hein-Rasmussen R Intensive Care Med. 2017; 43(11):1637-1647.

PMID: 28936712 DOI: 10.1007/s00134-017-4880-3.


The influence of metabolic imbalances and oxidative stress on the outcome of critically ill polytrauma patients: a review.

Rogobete A, Sandesc D, Papurica M, Stoicescu E, Popovici S, Bratu L Burns Trauma. 2017; 5:8.

PMID: 28286784 PMC: 5341432. DOI: 10.1186/s41038-017-0073-0.