» Articles » PMID: 27446683

Influence of Polarization Filtration on the Information Readout from Pulsating Blood Vessels

Overview
Specialty Radiology
Date 2016 Jul 23
PMID 27446683
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Imaging photoplethysmography (IPPG) is a recently developed technique for noncontact assessment of cardiovascular function. However, its wide use is limited by low signal-to-noise ratio due to motion artifacts. The aim of this work is to estimate the polarization-filtration impact on discriminating artifacts in IPPG measurements. Experiments were carried out in-vivo by almost simultaneous illumination of subject's palm with polarized and non-polarized light during video recording of 41 subjects. It was found that the light-polarization filtration efficiently reduces motion artifacts compared to the non-polarized illumination while the pulsation amplitude measured at the heartbeat frequency remains unaffected. The polarization filtration improves reliability of IPPG system in non-contact monitoring of subject's heart rate and its variability.

Citing Articles

Plethysmographic assessment of vasomotor response in patients with congestive heart failure before and after heart transplantation.

Mamontov O, Zaytsev V, Kamshilin A Biomed Opt Express. 2024; 15(2):687-699.

PMID: 38404348 PMC: 10890858. DOI: 10.1364/BOE.511925.


Duality in response of intracranial vessels to nitroglycerin revealed in rats by imaging photoplethysmography.

Sokolov A, Volynsky M, Potapenko A, Iurkova P, Zaytsev V, Nippolainen E Sci Rep. 2023; 13(1):11928.

PMID: 37488233 PMC: 10366118. DOI: 10.1038/s41598-023-39171-w.


Intraoperative visualization and quantitative assessment of tissue perfusion by imaging photoplethysmography: comparison with ICG fluorescence angiography.

Kashchenko V, Zaytsev V, Ratnikov V, Kamshilin A Biomed Opt Express. 2022; 13(7):3954-3966.

PMID: 35991934 PMC: 9352280. DOI: 10.1364/BOE.462694.


Novel Method to Assess Endothelial Function via Monitoring of Perfusion Response to Local Heating by Imaging Photoplethysmography.

Kamshilin A, Zaytsev V, Belaventseva A, Podolyan N, Volynsky M, Sakovskaia A Sensors (Basel). 2022; 22(15).

PMID: 35957284 PMC: 9370951. DOI: 10.3390/s22155727.


Study of cerebrovascular reactivity to hypercapnia by imaging photoplethysmography to develop a method for intraoperative assessment of the brain functional reserve.

Volynsky M, Mamontov O, Osipchuk A, Zaytsev V, Sokolov A, Kamshilin A Biomed Opt Express. 2022; 13(1):184-196.

PMID: 35154863 PMC: 8803018. DOI: 10.1364/BOE.443477.


References
1.
Wieringa F, Mastik F, van Der Steen A . Contactless multiple wavelength photoplethysmographic imaging: a first step toward "SpO2 camera" technology. Ann Biomed Eng. 2005; 33(8):1034-41. DOI: 10.1007/s10439-005-5763-2. View

2.
ODoherty J, McNamara P, Clancy N, Enfield J, Leahy M . Comparison of instruments for investigation of microcirculatory blood flow and red blood cell concentration. J Biomed Opt. 2009; 14(3):034025. DOI: 10.1117/1.3149863. View

3.
Karlsson M, Wardell K . Polarized laser Doppler perfusion imaging--reduction of movement-induced artifacts. J Biomed Opt. 2006; 10(6):064002. DOI: 10.1117/1.2120467. View

4.
Kamshilin A, Nippolainen E, Sidorov I, Vasilev P, Erofeev N, Podolian N . A new look at the essence of the imaging photoplethysmography. Sci Rep. 2015; 5:10494. PMC: 4440202. DOI: 10.1038/srep10494. View

5.
Xu S, Sun L, Rohde G . Robust efficient estimation of heart rate pulse from video. Biomed Opt Express. 2014; 5(4):1124-35. PMC: 3985994. DOI: 10.1364/BOE.5.001124. View