» Articles » PMID: 25657877

Non-contact Estimation of Heart Rate and Oxygen Saturation Using Ambient Light

Overview
Specialty Radiology
Date 2015 Feb 7
PMID 25657877
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

We propose a robust method for automated computation of heart rate (HR) from digital color video recordings of the human face. In order to extract photoplethysmographic signals, two orthogonal vectors of RGB color space are used. We used a dual tree complex wavelet transform based denoising algorithm to reduce artifacts (e.g. artificial lighting, movement, etc.). Most of the previous work on skin color based HR estimation performed experiments with healthy volunteers and focused to solve motion artifacts. In addition to healthy volunteers we performed experiments with child patients in pediatric intensive care units. In order to investigate the possible factors that affect the non-contact HR monitoring in a clinical environment, we studied the relation between hemoglobin levels and HR estimation errors. Low hemoglobin causes underestimation of HR. Nevertheless, we conclude that our method can provide acceptable accuracy to estimate mean HR of patients in a clinical environment, where the measurements can be performed remotely. In addition to mean heart rate estimation, we performed experiments to estimate oxygen saturation. We observed strong correlations between our SpO2 estimations and the commercial oximeter readings.

Citing Articles

MultiPhys: Heterogeneous Fusion of Mamba and Transformer for Video-Based Multi-Task Physiological Measurement.

Huo C, Yin P, Fu B Sensors (Basel). 2025; 25(1.

PMID: 39796891 PMC: 11722562. DOI: 10.3390/s25010100.


Innovative approaches in imaging photoplethysmography for remote blood oxygen monitoring.

Zhu S, Liu S, Jing X, Yang Y, She C Sci Rep. 2024; 14(1):19144.

PMID: 39160216 PMC: 11333616. DOI: 10.1038/s41598-024-70192-1.


A two-phased study on the use of remote photoplethysmography (rPPG) in paediatric care.

Ahmad Hatib N, Lee J, Chong S, Sng Q, Tan V, Ong G Ann Transl Med. 2024; 12(3):46.

PMID: 38911566 PMC: 11193567. DOI: 10.21037/atm-23-1896.


Imaging of the vascular distribution of the outer ear using optical coherence tomography angiography for highly accurate positioning of a hearable sensor.

Hong J, Seong D, Kang D, Kim H, Jang J, Jeon M APL Bioeng. 2024; 8(2):026113.

PMID: 38799376 PMC: 11126325. DOI: 10.1063/5.0203582.


Contactless Blood Oxygen Saturation Estimation from Facial Videos Using Deep Learning.

Cheng C, Yuen Z, Chen S, Wong K, Chin J, Chan T Bioengineering (Basel). 2024; 11(3).

PMID: 38534525 PMC: 10968547. DOI: 10.3390/bioengineering11030251.


References
1.
. Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Eur Heart J. 1996; 17(3):354-81. View

2.
Poh M, McDuff D, Picard R . Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Trans Biomed Eng. 2010; 58(1):7-11. DOI: 10.1109/TBME.2010.2086456. View

3.
Scully C, Lee J, Meyer J, Gorbach A, Granquist-Fraser D, Mendelson Y . Physiological parameter monitoring from optical recordings with a mobile phone. IEEE Trans Biomed Eng. 2011; 59(2):303-6. PMC: 3476722. DOI: 10.1109/TBME.2011.2163157. View

4.
Sun Y, Hu S, Azorin-Peris V, Kalawsky R, Greenwald S . Noncontact imaging photoplethysmography to effectively access pulse rate variability. J Biomed Opt. 2012; 18(6):061205. DOI: 10.1117/1.JBO.18.6.061205. View

5.
Cook S, Togni M, Schaub M, Wenaweser P, Hess O . High heart rate: a cardiovascular risk factor?. Eur Heart J. 2006; 27(20):2387-93. DOI: 10.1093/eurheartj/ehl259. View