Acute Vertebral Fracture After Spinal Fusion: a Case Report Illustrating the Added Value of Single-source Dual-energy Computed Tomography to Magnetic Resonance Imaging in a Patient with Spinal Instrumentation

Overview
Journal Skeletal Radiol
Specialties Orthopedics
Radiology
Date 2016 Jun 9
PMID 27270922
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic resonance imaging (MRI) is degraded by metal-implant-induced artifacts when used for the diagnostic assessment of vertebral compression fractures in patients with instrumented spinal fusion. Dual-energy computed tomography (DECT) offers a promising supplementary imaging tool in these patients. This case report describes an 85-year-old woman who presented with a suspected acute vertebral fracture after long posterior lumbar interbody fusion. This is the first report of a vertebral fracture that showed bone marrow edema on DECT; however, edema was missed by an MRI STIR sequence owing to metal artifacts. Bone marrow assessment using DECT is less susceptible to metal artifacts than MRI, resulting in improved visualization of vertebral edema in the vicinity of fused vertebral bodies.

Citing Articles

Rapid-kilovoltage-switching dual-energy computed tomography (CT) for differentiating spinal osteolytic metastases from spinal infections.

Yuan Y, Lang N, Yuan H Quant Imaging Med Surg. 2021; 11(2):620-627.

PMID: 33532262 PMC: 7779941. DOI: 10.21037/qims-20-334.


Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study.

Diekhoff T, Engelhard N, Fuchs M, Pumberger M, Putzier M, Mews J Eur Radiol. 2018; 29(1):31-39.

PMID: 29948088 DOI: 10.1007/s00330-018-5568-y.

References
1.
Haghighi R, Chatterjee S, Tabin M, Sharma S, Jagia P, Ray R . DECT evaluation of noncalcified coronary artery plaque. Med Phys. 2015; 42(10):5945-54. DOI: 10.1118/1.4929935. View

2.
Diekhoff T, Kiefer T, Stroux A, Pilhofer I, Juran R, Mews J . Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies. Invest Radiol. 2014; 50(4):255-60. DOI: 10.1097/RLI.0000000000000099. View

3.
Toprover M, Krasnokutsky S, Pillinger M . Gout in the Spine: Imaging, Diagnosis, and Outcomes. Curr Rheumatol Rep. 2015; 17(12):70. DOI: 10.1007/s11926-015-0547-7. View

4.
Adams J . Opportunistic Identification of Vertebral Fractures. J Clin Densitom. 2015; 19(1):54-62. DOI: 10.1016/j.jocd.2015.08.010. View

5.
Pache G, Krauss B, Strohm P, Saueressig U, Blanke P, Bulla S . Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study. Radiology. 2010; 256(2):617-24. DOI: 10.1148/radiol.10091230. View