» Articles » PMID: 27268082

Metal Artefact Reduction for Patients with Metallic Dental Fillings in Helical Neck Computed Tomography: Comparison of Adaptive Iterative Dose Reduction 3D (AIDR 3D), Forward-projected Model-based Iterative Reconstruction Solution (FIRST) and AIDR...

Overview
Date 2016 Jun 9
PMID 27268082
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: To compare the differences in metal artefact degree and the depiction of structures in helical neck CT, in patients with metallic dental fillings, among adaptive iterative dose reduction three dimensional (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR-A).

Methods: In this retrospective clinical study, 22 patients (males, 13; females, 9; mean age, 64.6 ± 12.6 years) with metallic dental fillings who underwent contrast-enhanced helical CT involving the oropharyngeal region were included. Neck axial images were reconstructed with AIDR 3D, FIRST and SEMAR-A. Metal artefact degree and depiction of structures (the apex and root of the tongue, parapharyngeal space, superior portion of the internal jugular chain and parotid gland) were evaluated on a four-point scale by two radiologists. Placing regions of interest, standard deviations of the oral cavity and nuchal muscle (at the slice where no metal exists) were measured and metal artefact indices were calculated (the square root of the difference of the squares of them).

Results: In SEMAR-A, metal artefact was significantly reduced and depictions of all structures were significantly improved compared with those in FIRST and AIDR 3D (p ≤ 0.001, sign test). Metal artefact index for the oral cavity in AIDR 3D/FIRST/SEMAR-A was 572.0/477.7/88.4, and significant differences were seen between each reconstruction algorithm (p < 0.0001, Wilcoxon signed-rank test).

Conclusions: SEMAR-A could provide images with lesser metal artefact and better depiction of structures than AIDR 3D and FIRST.

Citing Articles

Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants.

Suito H, Yoshihara H, Maeda N, Kasai R, Inoue T, Amano M Oral Radiol. 2025; .

PMID: 40038165 DOI: 10.1007/s11282-025-00814-5.


The estimation of coronary artery calcium thickness by computed tomography angiography based on optical coherence tomography measurements.

Okutsu M, Mitomo S, Onishi H, Nakajima A, Yabushita H, Matsuoka S Heart Vessels. 2023; 38(11):1305-1317.

PMID: 37422802 DOI: 10.1007/s00380-023-02286-1.


Microtomographic Analysis of a Palaeolithic Wooden Point from the Ljubljanica River.

Puhar E, Korat L, Eric M, Jaklic A, Solina F Sensors (Basel). 2022; 22(6).

PMID: 35336540 PMC: 8951160. DOI: 10.3390/s22062369.


Subtraction iodine imaging with area detector CT to improve tumor delineation and measurability of tumor size and depth of invasion in tongue squamous cell carcinoma.

Hiyama T, Kuno H, Sekiya K, Tsushima S, Oda S, Kobayashi T Jpn J Radiol. 2021; 40(2):167-176.

PMID: 34529215 PMC: 8803757. DOI: 10.1007/s11604-021-01196-4.


Metal artifacts reduction in computed tomography: A phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging.

Ishikawa T, Suzuki S, Harashima S, Fukui R, Kaiume M, Katada Y Medicine (Baltimore). 2020; 99(50):e23692.

PMID: 33327359 PMC: 7738054. DOI: 10.1097/MD.0000000000023692.


References
1.
Dong Y, Shi A, Wu J, Wang R, Sun L, Liu A . Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT. Eur Spine J. 2015; 25(6):1754-63. DOI: 10.1007/s00586-015-4053-4. View

2.
Morsbach F, Wurnig M, Kunz D, Krauss A, Schmidt B, Kollias S . Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions. Eur Radiol. 2013; 23(10):2687-94. DOI: 10.1007/s00330-013-2885-z. View

3.
Scott P, Loftus W, Kew J, Ahuja A, Yue V, van Hasselt C . Diagnosis of peritonsillar infections: a prospective study of ultrasound, computerized tomography and clinical diagnosis. J Laryngol Otol. 1999; 113(3):229-32. DOI: 10.1017/s0022215100143634. View

4.
Bamberg F, Dierks A, Nikolaou K, Reiser M, Becker C, Johnson T . Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol. 2011; 21(7):1424-9. DOI: 10.1007/s00330-011-2062-1. View

5.
Gong X, Meyer E, Yu X, Sun J, Sheng L, Huang K . Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT. Dentomaxillofac Radiol. 2013; 42(4):20120105. PMC: 3667513. DOI: 10.1259/dmfr.20120105. View