Investigation of Polymer-shelled Microbubble Motions in Acoustophoresis

Overview
Journal Ultrasonics
Specialty Radiology
Date 2016 Jun 5
PMID 27261567
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this paper is to explore the trajectory motion of microsize (typically smaller than a red blood cell) encapsulated polymer-shelled gas bubbles propelled by radiation force in an acoustic standing-wave field and to compare the corresponding movements of solid polymer microbeads. The experimental setup consists of a microfluidic chip coupled to a piezoelectric crystal (PZT) with a resonance frequency of about 2.8MHz. The microfluidic channel consists of a rectangular chamber with a width, w, corresponding to one wavelength of the ultrasound standing wave. It creates one full wave ultrasound of a standing-wave pattern with two pressure nodes at w/4 and 3w/4 and three antinodes at 0, w/2, and w. The peak-to-peak amplitude of the electrical potential over the PZT was varied between 1 and 10V. The study is limited to no-flow condition. From Gor'kov's potential equation, the acoustic contrast factor, Φ, for the polymer-shelled microbubbles was calculated to about -60.7. Experimental results demonstrate that the polymer-shelled microbubbles are translated and accumulated at the pressure antinode planes. This trajectory motion of polymer-shelled microbubbles toward the pressure antinode plane is similar to what has been described for other acoustic contrast particles with a negative Φ. First, primary radiation forces dragged the polymer-shelled microbubbles into proximity with each other at the pressure antinode planes. Then, primary and secondary radiation forces caused them to quickly aggregate at different spots along the channel. The relocation time for polymer-shelled microbubbles was 40 times shorter than that for polymer microbeads, and in contrast to polymer microbeads, the polymer-shelled microbubbles were actuated even at driving voltages (proportional to radiation forces) as low as 1V. In short, the polymer-shelled microbubbles demonstrate the behavior attributed to the negative acoustic contrast factor particles and thus can be trapped at the antinode plane and thereby separated from particles having a positive acoustic contrast factor, such as for example solid particles and cells. This phenomenon could be utilized in exploring future applications, such as bioassay, bioaffinity, and cell interaction studies in vitro in a well-controlled environment.

Citing Articles

Microfluidic Blood Separation: Key Technologies and Critical Figures of Merit.

Torres-Castro K, Acuna-Umana K, Lesser-Rojas L, Reyes D Micromachines (Basel). 2023; 14(11).

PMID: 38004974 PMC: 10672873. DOI: 10.3390/mi14112117.


Measuring the Compressibility of Cellulose Nanofiber-Stabilized Microdroplets Using Acoustophoresis.

Loskutova K, Olofsson K, Hammarstrom B, Wiklund M, Svagan A, Grishenkov D Micromachines (Basel). 2021; 12(12).

PMID: 34945315 PMC: 8707857. DOI: 10.3390/mi12121465.


Directed Assembly of Particles for Additive Manufacturing of Particle-Polymer Composites.

Shabaniverki S, Juarez J Micromachines (Basel). 2021; 12(8).

PMID: 34442557 PMC: 8401964. DOI: 10.3390/mi12080935.


MicroBubble activated acoustic cell sorting.

Faridi M, Ramachandraiah H, Iranmanesh I, Grishenkov D, Wiklund M, Russom A Biomed Microdevices. 2017; 19(2):23.

PMID: 28374278 PMC: 5378755. DOI: 10.1007/s10544-017-0157-4.