» Articles » PMID: 27190639

Repeatability and Reproducibility of Noninvasive Keratograph 5M Measurements in Patients with Dry Eye Disease

Overview
Journal J Ophthalmol
Publisher Wiley
Specialty Ophthalmology
Date 2016 May 19
PMID 27190639
Citations 57
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose. To determine the intraexaminer repeatability and interexaminer reproducibility of tear meniscus height (TMH) and noninvasive Keratograph tear breakup time (NIKBUT) measurements obtained with the Keratograph 5M (K5M) in a sample of healthy and dry eye populations. Methods. Forty-two patients with dry eye disease (DED group) and 42 healthy subjects (healthy group) were recruited in this prospective study. In all subjects, each eye received 3 consecutive measurements using the K5M for the TMH and NIKBUTs (NIKBUT-first and NIKBUT-average). And then a different examiner repeated the measurements. The repeatability and reproducibility of measurements were assessed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Results. The repeatability and reproducibility of TMH and NIKBUTs were good in both DED and healthy groups (CV% ≤ 26.1% and ICC ≥ 0.75 for all measurements). Patients with DED showed better intraexaminer repeatability for NIKBUTs, but worse for TMH than healthy subjects. Average TMH, NIKBUT-first, and NIKBUT-average were significantly lower in DED group than in healthy group (all P values < 0.05). Conclusions. Measurements of TMH and NIKBUTs obtained with the K5M may provide a simple, noninvasive screening test for dry eye with acceptable repeatability and reproducibility. The NIKBUTs were more reliable, but TMH was less reliable in patients with DED.

Citing Articles

Impact of religious fasting on ocular dryness: objective and subjective assessment.

Alomari A, Issa S, Musleh A, Abusamak M, Bdair O, AlRyalat S Front Med (Lausanne). 2025; 12:1488765.

PMID: 39975678 PMC: 11835933. DOI: 10.3389/fmed.2025.1488765.


Tear meniscus height comparison between AS-OCT and Oculus Keratograph® K5M.

Yik A, Barodawala F Rom J Ophthalmol. 2025; 68(4):398-403.

PMID: 39936048 PMC: 11809819. DOI: 10.22336/rjo.2024.72.


SMILE and ICL implantation on the ocular surface and meibomian glands in patients with postoperative myopia.

Yao J, Feng J, Li W, Liu C, Li Y, Wang X BMC Ophthalmol. 2024; 24(1):522.

PMID: 39633296 PMC: 11619467. DOI: 10.1186/s12886-024-03790-2.


High-Tech Parameters for the Evaluation of Signs and Symptoms of Dry Eye Disease: Identification of Clinical Cut-Offs and Agreement with Low-Tech Tests.

Fogagnolo P, Aragona P, Strianese A, Villani E, Giannaccare G, Orfeo V Ophthalmol Ther. 2024; 13(11):2999-3011.

PMID: 39340632 PMC: 11494620. DOI: 10.1007/s40123-024-01034-6.


Short-term effects of ophthalmic topical 0.01% atropine on the ocular surface, pupil size, and subsequent subjective quality of vision in young myopic Chinese adults.

Li M, Chen Y, Chen J, Qin G, Li L, He W Front Med (Lausanne). 2024; 11:1436551.

PMID: 39301485 PMC: 11412257. DOI: 10.3389/fmed.2024.1436551.


References
1.
Szczesna D, Jaronski J, Kasprzak H, Stenevi U . Interferometric measurements of dynamic changes of tear film. J Biomed Opt. 2006; 11(3):34028. DOI: 10.1117/1.2209881. View

2.
Koh S, Ikeda C, Watanabe S, Oie Y, Soma T, Watanabe H . Effect of non-invasive tear stability assessment on tear meniscus height. Acta Ophthalmol. 2014; 93(2):e135-9. DOI: 10.1111/aos.12516. View

3.
. Methodologies to diagnose and monitor dry eye disease: report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007). Ocul Surf. 2007; 5(2):108-52. DOI: 10.1016/s1542-0124(12)70083-6. View

4.
Bland J, Altman D . Measurement error. BMJ. 1996; 312(7047):1654. PMC: 2351401. DOI: 10.1136/bmj.312.7047.1654. View

5.
Savini G, Prabhawasat P, Kojima T, Grueterich M, Espana E, Goto E . The challenge of dry eye diagnosis. Clin Ophthalmol. 2009; 2(1):31-55. PMC: 2698717. DOI: 10.2147/opth.s1496. View