» Articles » PMID: 27185221

Positive-contrast Cellular MRI of Embryonic Stem Cells for Tissue Regeneration Using a Highly Efficient T MRI Contrast Agent

Overview
Date 2016 May 18
PMID 27185221
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the feasibility of high-sensitivity cellular MRI of embryonic stem (ES) cells using a novel cell permeable and cell retentive T contrast agent.

Materials And Methods: Mouse ES cells were labeled with a novel manganese porphyrin contrast agent, MnAMP, at 0.1 mM over 2 to 24 h and retained in contrast-free medium for up to 24 h postlabeling. MRI was performed on a 3 Tesla clinical scanner; T and T relaxation times were measured. Quantification of manganese content was performed using atomic absorption spectroscopy. Viability and proliferation assays were done for the longest labeling interval. Differentiation capacity was assessed using the hanging drop method to direct differentiation toward cardiomyocytes.

Results: MnAMP-labeled ES cells exhibited over a fourfold decrease in T compared with unlabeled cells, and maintained up to a threefold decrease 24 h postlabeling. Viability and proliferation were not affected. Most importantly, labeled ES cells differentiated into functional cardiomyocytes that exhibited normal contractility patterns.

Conclusion: MnAMP-based cellular MRI is a very high sensitivity T approach for cellular imaging. It has the potential for noninvasive in vivo monitoring of stem cell therapy in cardiac regeneration and other tissue engineering and regenerative medicine applications. J. Magn. Reson. Imaging 2016;44:1456-1463.

Citing Articles

A primer on cell tracking using MRI.

Cheng H Front Med (Lausanne). 2023; 10:1193459.

PMID: 37324153 PMC: 10264782. DOI: 10.3389/fmed.2023.1193459.


Iron (III)-Quercetin Complex: Synthesis, Physicochemical Characterization, and MRI Cell Tracking toward Potential Applications in Regenerative Medicine.

Papan P, Kantapan J, Sangthong P, Meepowpan P, Dechsupa N Contrast Media Mol Imaging. 2021; 2020:8877862.

PMID: 33456403 PMC: 7785384. DOI: 10.1155/2020/8877862.


An Efficient Contrast Agent for Labeling and Tracking Human Embryonic Stem Cells on MRI.

Haedicke I, Loai S, Cheng H Contrast Media Mol Imaging. 2019; 2019:3475786.

PMID: 31316306 PMC: 6604499. DOI: 10.1155/2019/3475786.


Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers.

Wahsner J, Gale E, Rodriguez-Rodriguez A, Caravan P Chem Rev. 2018; 119(2):957-1057.

PMID: 30350585 PMC: 6516866. DOI: 10.1021/acs.chemrev.8b00363.


A manganese porphyrin-based T1 contrast agent for cellular MR imaging of human embryonic stem cells.

Venter A, Szulc D, Loai S, Ganesh T, Haedicke I, Cheng H Sci Rep. 2018; 8(1):12129.

PMID: 30108285 PMC: 6092441. DOI: 10.1038/s41598-018-30661-w.