» Articles » PMID: 27157728

In Vitro Degradation of ZM21 Magnesium Alloy in Simulated Body Fluids

Overview
Publisher Elsevier
Date 2016 May 10
PMID 27157728
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

In vitro degradation behavior of squeeze cast (CAST) and equal channel angular pressed (ECAP) ZM21 magnesium alloy (2.0wt% Zn-0.98wt% Mn) was studied using immersion tests up to 4w in three different biological environments. Hanks' Balanced Salt Solution (Hanks), Earle's Balanced Salt Solution (Earle) and Eagle minimum essential medium supplemented with 10% (v/v) fetal bovine serum (E-MEM+10% FBS) were used to investigate the effect of carbonate buffer system, organic compounds and material processing on the degradation behavior of the ZM21 alloy samples. Corrosion rate of the samples was evaluated by their Mg(2+) ion release, weight loss and volume loss. In the first 24h, the corrosion rate sequence of the CAST samples was as following: Hanks>E-MEM+10% FBS>Earle. However, in longer immersion periods, the corrosion rate sequence was Earle>E-MEM+10% FBS≥Hanks. Strong buffering effect provided by carbonate buffer system helped to maintain the pH avoiding drastic increase of the corrosion rate of ZM21 in the initial stage of immersion. Organic compounds also contributed to maintain the pH of the fluid. Moreover, they adsorbed on the sample surface and formed an additional barrier on the insoluble salt layer, which was effective to retard the corrosion of CAST samples. In case of ECAP, however, this effect was overcome by the occurrence of strong localized corrosion due to the lower pH of the medium. Corrosion of ECAP samples was much greater than that of CAST, especially in Hanks, due to higher sensitivity of ECAP to localized corrosion and the presence of Cl(-). The present work demonstrates the importance of using an appropriate solution for a reliable estimation of the degradation rate of Mg-base degradable implants in biological environments, and concludes that the most appropriate solution for this purpose is E-MEM+10% FBS, which has the closest chemical composition to human blood plasma.

Citing Articles

Exploring the degradation behavior of MgXAg alloys by in vitro electrochemical methods.

Zhang Y, Zimmermann T, Mueller W, Witte F, Beuer F, Schwitalla A Bioact Mater. 2021; 7:441-452.

PMID: 34466744 PMC: 8379447. DOI: 10.1016/j.bioactmat.2021.05.044.


Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing.

Prithivirajan S, Nyahale M, Naik G, Narendranath S, Prabhu A, Rekha P J Mater Sci Mater Med. 2021; 32(6):65.

PMID: 34117928 PMC: 8197699. DOI: 10.1007/s10856-021-06535-5.


Effect of extrusion process on the mechanical and in vitro degradation performance of a biomedical Mg-Zn-Y-Nd alloy.

Du B, Hu Z, Wang J, Sheng L, Zhao H, Zheng Y Bioact Mater. 2020; 5(2):219-227.

PMID: 32123775 PMC: 7036737. DOI: 10.1016/j.bioactmat.2020.02.002.


Controlling the Degradation Rate of Biodegradable Mg-Zn-Mn Alloys for Orthopedic Applications by Electrophoretic Deposition of Hydroxyapatite Coating.

Antoniac I, Miculescu F, Cotrut C, Ficai A, Rau J, Grosu E Materials (Basel). 2020; 13(2).

PMID: 31936095 PMC: 7013831. DOI: 10.3390/ma13020263.


Biological Assessment of Zn-Based Absorbable Metals for Ureteral Stent Applications.

Paramitha D, Chabaud S, Bolduc S, Hermawan H Materials (Basel). 2019; 12(20).