» Articles » PMID: 27027775

Characterization and Correction of Geometric Distortions in 814 Diffusion Weighted Images

Overview
Journal PLoS One
Date 2016 Mar 31
PMID 27027775
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Diffusion Weighted Imaging (DWI), which is based on Echo Planar Imaging (EPI) protocols, is becoming increasingly important for neurosurgical applications. However, its use in this context is limited in part by significant spatial distortion inherent to EPI.

Method: We evaluated an efficient algorithm for EPI distortion correction (EPIC) across 814 DWI scans from 250 brain tumor patients and quantified the magnitude of geometric distortion for whole brain and multiple brain regions.

Results: Evaluation of the algorithm's performance revealed significantly higher mutual information between T1-weighted pre-contrast images and corrected b = 0 images than the uncorrected b = 0 images (p < 0.001). The distortion magnitude across all voxels revealed a median EPI distortion effect of 2.1 mm, ranging from 1.2 mm to 5.9 mm, the 5th and 95th percentile, respectively. Regions adjacent to bone-air interfaces, such as the orbitofrontal cortex, temporal poles, and brain stem, were the regions most severely affected by DWI distortion.

Conclusion: Using EPIC to estimate the degree of distortion in 814 DWI brain tumor images enabled the creation of a topographic atlas of DWI distortion across the brain. The degree of displacement of tumors boundaries in uncorrected images is severe but can be corrected for using EPIC. Our results support the use of distortion correction to ensure accurate and careful application of DWI to neurosurgical practice.

Citing Articles

Linguistic coupling between neural systems for speech production and comprehension during real-time dyadic conversations.

Zada Z, Nastase S, Speer S, Mwilambwe-Tshilobo L, Tsoi L, Burns S bioRxiv. 2025; .

PMID: 39990465 PMC: 11844503. DOI: 10.1101/2025.02.14.638276.


Longitudinal assessment of diffusion-weighted imaging during magnetic resonance-guided radiotherapy in head and neck cancer.

Boeke S, Habrich J, Kubler S, Boldt J, Schick F, Nikolaou K Radiat Oncol. 2025; 20(1):15.

PMID: 39881423 PMC: 11780986. DOI: 10.1186/s13014-025-02589-9.


Multi-study fMRI outlooks on subcortical BOLD responses in the stop-signal paradigm.

Isherwood S, Kemp S, Miletic S, Stevenson N, Bazin P, Forstmann B Elife. 2025; 12.

PMID: 39841120 PMC: 11753779. DOI: 10.7554/eLife.88652.


Prediction of pathological response and lymph node metastasis after neoadjuvant therapy in rectal cancer through tumor and mesorectal MRI radiomic features.

Qin S, Liu K, Chen Y, Zhou Y, Zhao W, Yan R Sci Rep. 2024; 14(1):21927.

PMID: 39304726 PMC: 11415499. DOI: 10.1038/s41598-024-72916-9.


Task-based functional neural correlates of social cognition across autism and schizophrenia spectrum disorders.

Oliver L, Moxon-Emre I, Hawco C, Dickie E, Dakli A, Lyon R Mol Autism. 2024; 15(1):37.

PMID: 39252047 PMC: 11385649. DOI: 10.1186/s13229-024-00615-3.


References
1.
Maes F, Vandermeulen D, Suetens P . Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information. Med Image Anal. 2000; 3(4):373-86. DOI: 10.1016/s1361-8415(99)80030-9. View

2.
Rakow-Penner R, White N, Margolis D, Parsons J, Schenker-Ahmed N, Kuperman J . Prostate diffusion imaging with distortion correction. Magn Reson Imaging. 2015; 33(9):1178-1181. PMC: 4594204. DOI: 10.1016/j.mri.2015.07.006. View

3.
Hutton C, Bork A, Josephs O, Deichmann R, Ashburner J, Turner R . Image distortion correction in fMRI: A quantitative evaluation. Neuroimage. 2002; 16(1):217-40. DOI: 10.1006/nimg.2001.1054. View

4.
Andersson J, Skare S, Ashburner J . How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage. 2003; 20(2):870-88. DOI: 10.1016/S1053-8119(03)00336-7. View

5.
Morgan P, Bowtell R, McIntyre D, Worthington B . Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method. J Magn Reson Imaging. 2004; 19(4):499-507. DOI: 10.1002/jmri.20032. View