» Articles » PMID: 26970833

The 21- to 27-year Results of the Harris-Galante Cementless Total Hip Arthroplasty

Overview
Journal J Orthop Sci
Publisher Elsevier
Specialty Orthopedics
Date 2016 Mar 14
PMID 26970833
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The Harris-Galante total hip arthroplasty (THA) is a first-generation cementless THA with a porous coating for biological fixation of the implant. Many studies report excellent long-term results for the acetabular cup, but few long-term studies exist for the femoral stem because of relatively poor short-term and midterm results. Here we present the 21- to 27-year results of the cup and the stem of the Harris-Galante THA.

Methods: From 1985 to 1991, 102 Harris-Galante THAs were inserted in 82 patients. At the time of the THA, the mean patient age was 54 years (range, 20-78 years). The primary diagnosis was secondary osteoarthritis due to developmental hip dysplasia (69 [68%] hips). The Japanese Orthopaedic Association (JOA) hip score and thigh pain were measures of clinical outcome. Radiographic review was performed retrospectively. Implant survival was evaluated by Kaplan-Meier analysis.

Results: Of 102 hips, 35 hips were from 31 deceased patients, 5 patients (6 hips) were lost to follow-up, 12 hips were revised, and 49 hips were from patients living at the latest follow-up. Among the living patients, 36 hips had a clinical evaluation and 42 hips had a radiograph obtained more than 21 years. The JOA hip score improved from 42 points preoperatively to 83.5 points at the latest follow-up. Thigh pain was reported in 13 hips. One cup and four stems were loose at the latest radiographic review. Most cup revisions were related to acetabular osteolysis. Fifteen hips showed severe stress shielding. Kaplan-Meier analysis of survivorship with any revision, acetabular reoperation, stem revision, and stem loosening as the end point was 87.0%, 90.3%, 95.7% and 86.4%, respectively, at 24.6 years.

Conclusions: Long-term implant survival and clinical results of the Harris-Galante THA were good. Acetabular osteolysis-related cup loosening was a problem of the cup. Loosening, thigh pain, and stress shielding were problems of the stem.

Citing Articles

Mid-term outcomes of compaction autologous bone grafting in uncemented primary total hip replacement stems.

Abe S, Inoue M, Mikami T, Honke H, Suzuki M, Kanno T Arch Orthop Trauma Surg. 2024; 145(1):29.

PMID: 39666038 PMC: 11638313. DOI: 10.1007/s00402-024-05640-8.


Average 22-Year Results of Total Hip Arthroplasty Using Harris-Galante Prosthesis in Patients under 50 Years.

Won H, Baek S, Kim J, Lee W, Lee Y, Kim S Clin Orthop Surg. 2022; 14(3):335-343.

PMID: 36061837 PMC: 9393279. DOI: 10.4055/cios21176.


Does Additive Pressurized Carbon Dioxide Lavage Improve Cement Penetration and Bond Strength in Cemented Arthroplasty?.

Knappe K, Stadler C, Innmann M, Schonhoff M, Gotterbarm T, Renkawitz T J Clin Med. 2021; 10(22).

PMID: 34830643 PMC: 8620516. DOI: 10.3390/jcm10225361.


Long-Term results of total Hip Arthroplasty performed using a cementless expansive Acetabular Cup and Spotorno Femoral Stem.

Carkci E, Polat A, Ozturkmen Y, Tuzuner T Pak J Med Sci. 2021; 37(1):52-58.

PMID: 33437250 PMC: 7794123. DOI: 10.12669/pjms.37.1.3089.


Prosthetic femoral head erosion through an acetabular component treated with revision and implant preservation.

Kohn M, Fernando N Arthroplast Today. 2020; 6(1):9-13.

PMID: 32211468 PMC: 7083747. DOI: 10.1016/j.artd.2019.12.003.