» Articles » PMID: 26933998

Dosimetric Impact of Intermediate Dose Calculation for Optimization Convergence Error

Overview
Journal Oncotarget
Specialty Oncology
Date 2016 Mar 3
PMID 26933998
Authors
Affiliations
Soon will be listed here.
Abstract

Intensity-modulated radiation therapy (IMRT) provides the protection of the normal organs and a precise treatment plan through its optimization process. However, the final dose-volume histogram (DVH) obtained by this technique differs from the optimal DVH, owing to optimization convergence errors. Herein, intermediate dose calculation was applied to IMRT plans during the optimization process to solve these issues.Homogeneous and heterogeneous targets were delineated on a virtual phantom, and the final DVH for the target volume was assessed on the target coverage. The IMRT plans of 30 patients were established to evaluate the usefulness of intermediate dose calculation.The target coverage results were analogous in the three plans with homogeneous targets. Conversely, conformity indices (conformity index [CI], heterogeneity index [HI], and uniformity index [UI]) of plans with intermediate dose calculation were estimated to be more homogenous than plans without this option for heterogeneous targets (CI, 0.371 vs. 1.000; HI, 0.104 vs. 0.036; UI, 1.099 vs. 1.031 for Phantom B; and CI, 0.318 vs. 0.956; HI, 0.167 vs. 0.076; UI, 1.165 vs. 1.057 for Phantom C). In brain and prostate cancers, a slight difference between plans calculated with anisotropic analytical algorithm (AAA) was observed (HI, p = 0.043, UI, p = 0.043 for brain; HI, p = 0.042, UI, p = 0.043 for prostate). All target coverage indices were improved by intermediate dose calculation in lung cancer cases (p = 0.043).In conclusion, intermediate dose calculation in IMRT plans improves the target coverage in the target volume around heterogeneous materials. Moreover, the optimization time can be reduced.

References
1.
Tillikainen L, Helminen H, Torsti T, Siljamaki S, Alakuijala J, Pyyry J . A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media. Phys Med Biol. 2008; 53(14):3821-39. DOI: 10.1088/0031-9155/53/14/008. View

2.
Han T, Mourtada F, Kisling K, Mikell J, Followill D, Howell R . Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom. Med Phys. 2012; 39(4):2193-202. PMC: 3337663. DOI: 10.1118/1.3692180. View

3.
Vanetti E, Nicolini G, Nord J, Peltola J, Clivio A, Fogliata A . On the role of the optimization algorithm of RapidArc(®) volumetric modulated arc therapy on plan quality and efficiency. Med Phys. 2011; 38(11):5844-56. DOI: 10.1118/1.3641866. View

4.
Otto K . Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008; 35(1):310-7. DOI: 10.1118/1.2818738. View

5.
MacDonald S, Ahmad S, Kachris S, Vogds B, DeRouen M, Gittleman A . Intensity modulated radiation therapy versus three-dimensional conformal radiation therapy for the treatment of high grade glioma: a dosimetric comparison. J Appl Clin Med Phys. 2007; 8(2):47-60. PMC: 5722415. DOI: 10.1120/jacmp.v8i2.2423. View