» Articles » PMID: 26898593

Effects of Indigo Carmine Intravenous Injection on Noninvasive and Continuous Total Hemoglobin Measurement with Using the Revision L Sensor

Overview
Publisher Springer
Date 2016 Feb 23
PMID 26898593
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

The effects of intravenous injection of indigo carmine on noninvasive and continuous total hemoglobin (SpHb) measurement were retrospectively evaluated with the Revision L sensor. The subjects were 18 patients who underwent elective gynecologic surgery under general anesthesia. During surgery, 5 mL of 0.4 % indigo carmine was injected intravenously, and changes in SpHb concentrations between before and after the injection were evaluated. The mean age was 52.4 ± 12.8 years. Before injection, the median SpHb level was 10.1 (range, 6.8-13.4) g/dL. The results demonstrated no change in SpHb concentration between before and after indigo carmine injection as detected by the Revision L sensor. SpHb measurements as determined with the Revision L sensor were not affected, even after the intravenous injection of indigo carmine.

Citing Articles

Accuracy of Continuous and Noninvasive Hemoglobin Monitoring in the Presence of CO2 Insufflation: An Observational Pilot Study.

Lee H, Yoo J, Kim H, Kim N, Kim J Med Sci Monit. 2021; 27:e933027.

PMID: 34702795 PMC: 8559297. DOI: 10.12659/MSM.933027.


Effects of indigo carmine intravenous injection on oxygen reserve index (ORi™) measurement.

Isosu T, Yoshida K, Oishi R, Imaizumi T, Iseki Y, Sanbe N J Clin Monit Comput. 2017; 32(4):693-697.

PMID: 28975476 DOI: 10.1007/s10877-017-0064-5.

References
1.
Scheller M, Unger R, Kelner M . Effects of intravenously administered dyes on pulse oximetry readings. Anesthesiology. 1986; 65(5):550-2. DOI: 10.1097/00000542-198611000-00023. View

2.
Berkow L, Rotolo S, Mirski E . Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg. 2011; 113(6):1396-402. DOI: 10.1213/ANE.0b013e318230b425. View

3.
Isosu T, Obara S, Hosono A, Ohashi S, Nakano Y, Imaizumi T . Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput. 2012; 27(1):55-60. DOI: 10.1007/s10877-012-9397-2. View

4.
Miller R, Ward T, Shiboski S, Cohen N . A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011; 112(4):858-63. DOI: 10.1213/ANE.0b013e31820eecd1. View

5.
Macknet M, Allard M, Applegate 2nd R, Rook J . The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution. Anesth Analg. 2010; 111(6):1424-6. DOI: 10.1213/ANE.0b013e3181fc74b9. View