Abstract

Background: Polyetheretherketone (PEEK) rod system is a novel pedicle-based dynamic stabilization system. This study evaluated clinical and radiographic outcomes of non-fusion surgery by PEEK rod systems for treatment of degenerative lumbar diseases with a 2-year follow-up.

Methods: From February 2012 to October 2012, 38 patients who underwent non-fusion surgery using PEEK rod systems were included in the study. Data on Oswestry Disability Index (ODI) score and Japanese Orthopaedics Association (JOA) score were collected and radiographs were obtained to evaluate disc height index (DHI) and range of motion (ROM) at each interval.

Results: Both JOA and ODI scores significantly improved postoperatively. DHI showed a slight increase immediately after the surgery but gradually dropped below preoperative levels. Mean ROM values changed from 8.8° preoperatively to 1.8° at the 2-year follow-up point. Screw loosening occurred in one case at the 2-year follow-up.

Conclusions: The preliminary results indicated a significant improvement in clinical outcomes and advantageous implant safety. The non-fusion procedure using PEEK rod systems might be a viable alternative for treatment of lumbar degenerative diseases. The distraction technique needs to be improved for better postoperative DHI.

Citing Articles

Comparison of biomechanical effects of polyetheretherketone (PEEK) rods and titanium rods in lumbar long-segment instrumentation: a finite element study.

Li C, Zhao Y, Qi L, Xu B, Yue L, Zhu R Front Bioeng Biotechnol. 2024; 12:1416046.

PMID: 39055340 PMC: 11269095. DOI: 10.3389/fbioe.2024.1416046.


Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score.

Jiang G, Xu L, Ma Y, Guan J, Yang Y, Zhong W Neurospine. 2024; 21(2):712-720.

PMID: 38955540 PMC: 11224750. DOI: 10.14245/ns.2448184.092.


Retrieval analysis of PEEK rods pedicle screw system: three cases analysis.

Xu X, Wang L, Wang J, Yu X, Huang W BMC Musculoskelet Disord. 2024; 25(1):488.

PMID: 38909212 PMC: 11193296. DOI: 10.1186/s12891-024-07600-0.


Nucleus high intensity in the T2-weighted MRI is a potential predictor of annulus tear in cervical injured patients: a case comparative study.

Wan S, Zhang J, Wu C, Lin X, Li J, Wu F BMC Musculoskelet Disord. 2023; 24(1):602.

PMID: 37488519 PMC: 10364398. DOI: 10.1186/s12891-023-06615-3.


Biomechanical effects of screws of different materials on vertebra-pediculoplasty: a finite element study.

Wang Y, Ren Y, Han J, Chen C, Sun X, Di M Front Bioeng Biotechnol. 2023; 11:1225925.

PMID: 37456721 PMC: 10340523. DOI: 10.3389/fbioe.2023.1225925.


References
1.
Cienciala J, Chaloupka R, Repko M, Krbec M . [Dynamic neutralization using the Dynesys system for treatment of degenerative disc disease of the lumbar spine]. Acta Chir Orthop Traumatol Cech. 2010; 77(3):203-8. View

2.
Kurtz S, Lanman T, Higgs G, MacDonald D, Berven S, Isaza J . Retrieval analysis of PEEK rods for posterior fusion and motion preservation. Eur Spine J. 2013; 22(12):2752-9. PMC: 3843804. DOI: 10.1007/s00586-013-2920-4. View

3.
Jahng T, Kim Y, Moon K . Comparison of the biomechanical effect of pedicle-based dynamic stabilization: a study using finite element analysis. Spine J. 2012; 13(1):85-94. DOI: 10.1016/j.spinee.2012.11.014. View

4.
Lee S, Park S, Jahng T, Chung C, Kim H . Clinical experience of the dynamic stabilization system for the degenerative spine disease. J Korean Neurosurg Soc. 2008; 43(5):221-6. PMC: 2588217. DOI: 10.3340/jkns.2008.43.5.221. View

5.
Kocak T, Cakir B, Reichel H, Mattes T . Screw loosening after posterior dynamic stabilization--review of the literature. Acta Chir Orthop Traumatol Cech. 2010; 77(2):134-9. View