In Vitro RABiT Measurement of Dose Rate Effects on Radiation Induction of Micronuclei in Human Peripheral Blood Lymphocytes

Overview
Date 2016 Jan 22
PMID 26791381
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Developing new methods for radiation biodosimetry has been identified as a high-priority need in case of a radiological accident or nuclear terrorist attacks. A large-scale radiological incident would result in an immediate critical need to assess the radiation doses received by thousands of individuals. Casualties will be exposed to different doses and dose rates due to their geographical position and sheltering conditions, and dose rate is one of the principal factors that determine the biological consequences of a given absorbed dose. In these scenarios, high-throughput platforms are required to identify the biological dose in a large number of exposed individuals for clinical monitoring and medical treatment. The Rapid Automated Biodosimetry Tool (RABiT) is designed to be completely automated from the input of blood sample into the machine to the output of a dose estimate. The primary goal of this paper was to quantify the dose rate effects for RABiT-measured micronuclei in vitro in human lymphocytes. Blood samples from healthy volunteers were exposed in vitro to different doses of X-rays to acute and protracted doses over a period up to 24 h. The acute dose was delivered at ~1.03 Gy/min and the low dose rate exposure at ~0.31 Gy/min. The results showed that the yield of micronuclei decreases with decreasing dose rate starting at 2 Gy, whereas response was indistinguishable from that of acute exposure in the low dose region, up to 0.5 Gy. The results showed a linear-quadratic dose-response relationship for the occurrence of micronuclei for the acute exposure and a linear dose-response relationship for the low dose rate exposure.

Citing Articles

X-ray and DNA Damage: Limitations of the Dose as a Parameter for In Vitro Studies.

Udroiu I, Sgura A Int J Mol Sci. 2023; 24(23).

PMID: 38068965 PMC: 10706214. DOI: 10.3390/ijms242316643.


Sex and dose rate effects in automated cytogenetics.

Garty G, Royba E, Repin M, Shuryak I, Deoli N, Obaid R Radiat Prot Dosimetry. 2023; 199(14):1495-1500.

PMID: 37721073 PMC: 10505938. DOI: 10.1093/rpd/ncac286.


Variable Dose Rates in Realistic Radiation Exposures: Effects on Small Molecule Markers of Ionizing Radiation in the Murine Model.

Pannkuk E, Laiakis E, Garty G, Ponnaiya B, Wu X, Shuryak I Radiat Res. 2023; 200(1):1-12.

PMID: 37212727 PMC: 10410530. DOI: 10.1667/RADE-22-00211.1.


Ultra-high dose rate FLASH irradiator at the radiological research accelerator facility.

Garty G, Obaid R, Deoli N, Royba E, Tan Y, Harken A Sci Rep. 2022; 12(1):22149.

PMID: 36550150 PMC: 9780319. DOI: 10.1038/s41598-022-19211-7.


A machine learning method for improving the accuracy of radiation biodosimetry by combining data from the dicentric chromosomes and micronucleus assays.

Shuryak I, Royba E, Repin M, Turner H, Garty G, Deoli N Sci Rep. 2022; 12(1):21077.

PMID: 36473912 PMC: 9726929. DOI: 10.1038/s41598-022-25453-2.


References
1.
Thierens H, De Ruyck K, Vral A, de Gelder V, Whitehouse C, Tawn E . Cytogenetic biodosimetry of an accidental exposure of a radiological worker using multiple assays. Radiat Prot Dosimetry. 2005; 113(4):408-14. DOI: 10.1093/rpd/nch483. View

2.
Pellmar T, Rockwell S . Priority list of research areas for radiological nuclear threat countermeasures. Radiat Res. 2004; 163(1):115-23. DOI: 10.1667/rr3283. View

3.
Geard C, Chen C . Micronuclei and clonogenicity following low- and high-dose-rate gamma irradiation of normal human fibroblasts. Radiat Res. 1990; 124(1 Suppl):S56-61. View

4.
Jaworska A, Ainsbury E, Fattibene P, Lindholm C, Oestreicher U, Rothkamm K . Operational guidance for radiation emergency response organisations in Europe for using biodosimetric tools developed in EU MULTIBIODOSE project. Radiat Prot Dosimetry. 2014; 164(1-2):165-9. DOI: 10.1093/rpd/ncu294. View

5.
Garty G, Chen Y, Salerno A, Turner H, Zhang J, Lyulko O . The RABIT: a rapid automated biodosimetry tool for radiological triage. Health Phys. 2010; 98(2):209-17. PMC: 2923588. DOI: 10.1097/HP.0b013e3181ab3cb6. View