In Vitro RABiT Measurement of Dose Rate Effects on Radiation Induction of Micronuclei in Human Peripheral Blood Lymphocytes
Overview
Environmental Health
Oncology
Radiology
Affiliations
Developing new methods for radiation biodosimetry has been identified as a high-priority need in case of a radiological accident or nuclear terrorist attacks. A large-scale radiological incident would result in an immediate critical need to assess the radiation doses received by thousands of individuals. Casualties will be exposed to different doses and dose rates due to their geographical position and sheltering conditions, and dose rate is one of the principal factors that determine the biological consequences of a given absorbed dose. In these scenarios, high-throughput platforms are required to identify the biological dose in a large number of exposed individuals for clinical monitoring and medical treatment. The Rapid Automated Biodosimetry Tool (RABiT) is designed to be completely automated from the input of blood sample into the machine to the output of a dose estimate. The primary goal of this paper was to quantify the dose rate effects for RABiT-measured micronuclei in vitro in human lymphocytes. Blood samples from healthy volunteers were exposed in vitro to different doses of X-rays to acute and protracted doses over a period up to 24 h. The acute dose was delivered at ~1.03 Gy/min and the low dose rate exposure at ~0.31 Gy/min. The results showed that the yield of micronuclei decreases with decreasing dose rate starting at 2 Gy, whereas response was indistinguishable from that of acute exposure in the low dose region, up to 0.5 Gy. The results showed a linear-quadratic dose-response relationship for the occurrence of micronuclei for the acute exposure and a linear dose-response relationship for the low dose rate exposure.
X-ray and DNA Damage: Limitations of the Dose as a Parameter for In Vitro Studies.
Udroiu I, Sgura A Int J Mol Sci. 2023; 24(23).
PMID: 38068965 PMC: 10706214. DOI: 10.3390/ijms242316643.
Sex and dose rate effects in automated cytogenetics.
Garty G, Royba E, Repin M, Shuryak I, Deoli N, Obaid R Radiat Prot Dosimetry. 2023; 199(14):1495-1500.
PMID: 37721073 PMC: 10505938. DOI: 10.1093/rpd/ncac286.
Pannkuk E, Laiakis E, Garty G, Ponnaiya B, Wu X, Shuryak I Radiat Res. 2023; 200(1):1-12.
PMID: 37212727 PMC: 10410530. DOI: 10.1667/RADE-22-00211.1.
Ultra-high dose rate FLASH irradiator at the radiological research accelerator facility.
Garty G, Obaid R, Deoli N, Royba E, Tan Y, Harken A Sci Rep. 2022; 12(1):22149.
PMID: 36550150 PMC: 9780319. DOI: 10.1038/s41598-022-19211-7.
Shuryak I, Royba E, Repin M, Turner H, Garty G, Deoli N Sci Rep. 2022; 12(1):21077.
PMID: 36473912 PMC: 9726929. DOI: 10.1038/s41598-022-25453-2.