» Articles » PMID: 26774615

Trade-off Between Angular and Spatial Resolutions in in Vivo Fiber Tractography

Overview
Journal Neuroimage
Specialty Radiology
Date 2016 Jan 18
PMID 26774615
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Tractography is becoming an increasingly popular method to reconstruct white matter connections in vivo. The diffusion MRI data that tractography is based on requires a high angular resolution to resolve crossing fibers whereas high spatial resolution is required to distinguish kissing from crossing fibers. However, scan time increases with increasing spatial and angular resolutions, which can become infeasible in clinical settings. Here we investigated the trade-off between spatial and angular resolutions to determine which of these factors is most worth investing scan time in. We created a unique diffusion MRI dataset with 1.0 mm isotropic resolution and a high angular resolution (100 directions) using an advanced 3D diffusion-weighted multi-slab EPI acquisition. This dataset was reconstructed to create subsets of lower angular (75, 50, and 25 directions) and lower spatial (1.5, 2.0, and 2.5 mm) resolution. Using all subsets, we investigated the effects of angular and spatial resolutions in three fiber bundles-the corticospinal tract, arcuate fasciculus and corpus callosum-by analyzing the volumetric bundle overlap and anatomical correspondence between tracts. Our results indicate that the subsets of 25 and 50 directions provided inferior tract reconstructions compared with the datasets with 75 and 100 directions. Datasets with spatial resolutions of 1.0, 1.5, and 2.0 mm were comparable, while the lowest resolution (2.5 mm) datasets had discernible inferior quality. In conclusion, we found that angular resolution appeared to be more influential than spatial resolution in improving tractography results. Spatial resolutions higher than 2.0 mm only appear to benefit multi-fiber tractography methods if this is not at the cost of decreased angular resolution.

Citing Articles

Super-resolution mapping of anisotropic tissue structure with diffusion MRI and deep learning.

Ordinola A, Abramian D, Herberthson M, Eklund A, Ozarslan E Sci Rep. 2025; 15(1):6580.

PMID: 39994322 PMC: 11850900. DOI: 10.1038/s41598-025-90972-7.


Surface-based tracking for short association fibre tractography.

Shastin D, Genc S, Parker G, Koller K, Tax C, Evans J Neuroimage. 2022; 260:119423.

PMID: 35809886 PMC: 10009610. DOI: 10.1016/j.neuroimage.2022.119423.


Fast Fiber Orientation Estimation in Diffusion MRI from kq-Space Sampling and Anatomical Priors.

Pesce M, Repetti A, Auria A, Daducci A, Thiran J, Wiaux Y J Imaging. 2021; 7(11).

PMID: 34821857 PMC: 8618762. DOI: 10.3390/jimaging7110226.


The Role of White Matter in the Neural Control of Swallowing: A Systematic Review.

Alvar A, Arkenberg R, McGowan B, Cheng H, Malandraki G Front Hum Neurosci. 2021; 15:628424.

PMID: 34262441 PMC: 8273764. DOI: 10.3389/fnhum.2021.628424.


Diffusion tractography for awake craniotomy: accuracy and factors affecting specificity.

Voets N, Pretorius P, Birch M, Apostolopoulos V, Stacey R, Plaha P J Neurooncol. 2021; 153(3):547-557.

PMID: 34196915 PMC: 8280000. DOI: 10.1007/s11060-021-03795-7.


References
1.
Chang H, Fitzpatrick J . A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE Trans Med Imaging. 1992; 11(3):319-29. DOI: 10.1109/42.158935. View

2.
Dayan M, Kreutzer S, Clark C . Tractography of the optic radiation: a repeatability and reproducibility study. NMR Biomed. 2015; 28(4):423-31. DOI: 10.1002/nbm.3266. View

3.
Sherbondy A, Dougherty R, Ben-Shachar M, Napel S, Wandell B . ConTrack: finding the most likely pathways between brain regions using diffusion tractography. J Vis. 2008; 8(9):15.1-16. PMC: 2696074. DOI: 10.1167/8.9.15. View

4.
Descoteaux M, Deriche R, Knosche T, Anwander A . Deterministic and probabilistic tractography based on complex fibre orientation distributions. IEEE Trans Med Imaging. 2009; 28(2):269-86. DOI: 10.1109/TMI.2008.2004424. View

5.
Parker G, Marshall D, Rosin P, Drage N, Richmond S, Jones D . A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data. Neuroimage. 2012; 65:433-48. PMC: 3580290. DOI: 10.1016/j.neuroimage.2012.10.022. View