» Articles » PMID: 26741022

A Digital-Analog Microfluidic Platform for Patient-Centric Multiplexed Biomarker Diagnostics of Ultralow Volume Samples

Overview
Journal ACS Nano
Specialty Biotechnology
Date 2016 Jan 8
PMID 26741022
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Microfluidic diagnostic devices have the potential to transform the practice of medicine. We engineered a multiplexed digital-analog microfluidic platform for the rapid and highly sensitive detection of 3-4 biomarkers in quadruplicate in 16 independent and isolated microfluidic unit cells requiring only a single 5 μL sample. We comprehensively characterized the platform by performing single enzyme and digital immunoassays, achieving single molecule detection and measured as low as ∼10 fM (330 fg/mL) GFP in buffer and ∼12 fM GFP in human serum. We applied our integrated digital detection mechanism to multiplexed detection of 1pM anti-Ebola IgG in human serum and were able to differentiate three common Ebola strains. To ascertain that the device can be applied in environments beyond clinical point-of-care settings, we developed a low-cost, portable hardware system to control and read out the microfluidic device and detected anti-Ebola IgG in ultralow volume whole blood samples to levels of 100 pM in a multiplexed assay format.

Citing Articles

Bio-energy-powered microfluidic devices.

Li Y, Xu C, Liao Y, Chen X, Chen J, Yang F Biomicrofluidics. 2024; 18(6):061303.

PMID: 39734663 PMC: 11672206. DOI: 10.1063/5.0227248.


Multiplexed Detection of Pancreatic Cancer by Combining a Nanoparticle-Enabled Blood Test and Plasma Levels of Acute-Phase Proteins.

Caputo D, Coppola A, Quagliarini E, Di Santo R, Capriotti A, Cammarata R Cancers (Basel). 2022; 14(19).

PMID: 36230585 PMC: 9563576. DOI: 10.3390/cancers14194658.


A role for microfluidic systems in precision medicine.

Ayuso J, Virumbrales-Munoz M, Lang J, Beebe D Nat Commun. 2022; 13(1):3086.

PMID: 35654785 PMC: 9163169. DOI: 10.1038/s41467-022-30384-7.


Spectral image contrast-based flow digital nanoplasmon-metry for ultrasensitive antibody detection.

Wang S, Kuo C, Lo S, Yeung W, Chang T, Wei P J Nanobiotechnology. 2022; 20(1):6.

PMID: 34983543 PMC: 8724237. DOI: 10.1186/s12951-021-01188-6.


Multistage Digital-to-Analogue Chip Based on a Weighted Flow Resistance Network for Soft Actuators.

Zhou Z, Xu M, Zhu C, He G, Zhang K, Sun D Micromachines (Basel). 2021; 12(9).

PMID: 34577660 PMC: 8465357. DOI: 10.3390/mi12091016.