» Articles » PMID: 26718184

Four-stage (low-)flow Modulation Comprehensive Gas Chromatography-quadrupole Mass Spectrometry for the Determination of Recently-highlighted Cosmetic Allergens

Overview
Journal J Chromatogr A
Publisher Elsevier
Specialty Chemistry
Date 2016 Jan 1
PMID 26718184
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The present research is based on the development and use of a flow-modulation (FM) comprehensive two-dimensional gas chromatography-quadrupole mass spectrometry (GC×GC-qMS) method for the determination of recently-highlighted (by the Scientific Committee on Consumer Safety) fragrance allergens (54) in cosmetics. FM GC×GC-qMS conditions were finely tuned to generate flow conditions (≈7 mL min(-1)) compatible with the qMS system used. Six-point calibration curves, over the range 1, 5, 10, 20, 50, 100 mg L(-1), were constructed for the 54 target allergens, with satisfactory linearity observed in all cases. Absolute quantification was performed by using extracted ions; target analyte identification was performed through measurement of ion ratios (qualifier/quantifier), full-scan MS database matching and the use of linear retention indices. Additional analytical figures of merit subjected to measurement were intra-day repeatability, accuracy at the 25 and 5 mg L(-1) levels, and limits of detection and quantification. The number of data points per peak, along with mass spectral skewing, was also subjected to evaluation. Finally, the FM GC×GC-qMS method was used not only for the quantification of target allergens in five commercial perfumes, but also for general qualitative profiling.

Citing Articles

Mass-Spectrometry-Based Research of Cosmetic Ingredients.

Serb A, Georgescu M, Onulov R, Novaconi C, Sisu E, Bolocan A Molecules. 2024; 29(6).

PMID: 38542972 PMC: 10974329. DOI: 10.3390/molecules29061336.


Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions.

Seeley J, Schimmel N, Seeley S Anal Bioanal Chem. 2022; 415(13):2399-2409.

PMID: 36301331 DOI: 10.1007/s00216-022-04387-8.


Review of New Trends in the Analysis of Allergenic Residues in Foods and Cosmetic Products.

Tuzimski T, Petruczynik A J AOAC Int. 2020; 103(4):997-1028.

PMID: 33241349 PMC: 8370415. DOI: 10.1093/jaoacint/qsaa015.


Good quantification practices of flavours and fragrances by mass spectrometry.

Begnaud F, Chaintreau A Philos Trans A Math Phys Eng Sci. 2016; 374(2079).

PMID: 27644977 PMC: 5031632. DOI: 10.1098/rsta.2015.0365.