This paper introduces a method for the robust estimation of foot clearance during walking, using a single inertial measurement unit (IMU) placed on the subject's foot. The proposed solution is based on double integration and drift cancellation of foot acceleration signals. The method is insensitive to misalignment of IMU axes with respect to foot axes. Details are provided regarding calibration and signal processing procedures. Experimental validation was performed on 10 healthy subjects under three walking conditions: normal, fast and with obstacles. Foot clearance estimation results were compared to measurements from an optical motion capture system. The mean error between them is significantly less than 15 % under the various walking conditions.

Citing Articles

Enhancing Intelligent Shoes with Gait Analysis: A Review on the Spatiotemporal Estimation Techniques.

Joseph A, Kian A, Begg R Sensors (Basel). 2025; 24(24.

PMID: 39771619 PMC: 11678955. DOI: 10.3390/s24247880.


Comparing the Ground Reaction Forces, Toe Clearances, and Stride Lengths of Young and Older Adults Using a Novel Shoe Sensor System.

Matsumoto H, Tomosada M, Nishi T, Sasaki Y, Sakurai R, Yamaguchi T Sensors (Basel). 2024; 24(21).

PMID: 39517766 PMC: 11548219. DOI: 10.3390/s24216871.


The Zero-Velocity Correction Method for Pipe Jacking Automatic Guidance System Based on Fiber Optic Gyroscope.

Zhang W, Wang L, Zu Y Sensors (Basel). 2024; 24(18).

PMID: 39338656 PMC: 11435479. DOI: 10.3390/s24185911.


Estimation of minimum foot clearance using a single foot-mounted inertial sensor and personalized foot geometry scan.

Fehr K, Bartloff J, Wang Y, Hetzel S, Adamczyk P Sci Rep. 2024; 14(1):13640.

PMID: 38871746 PMC: 11637083. DOI: 10.1038/s41598-024-63124-6.


Impact-Aware Foot Motion Reconstruction and Ramp/Stair Detection Using One Foot-Mounted Inertial Measurement Unit.

Wang Y, Fehr K, Adamczyk P Sensors (Basel). 2024; 24(5).

PMID: 38475012 PMC: 10935050. DOI: 10.3390/s24051480.


References
1.
Kotiadis D, Hermens H, Veltink P . Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection. Med Eng Phys. 2010; 32(4):287-97. DOI: 10.1016/j.medengphy.2009.10.014. View

2.
Seel T, Raisch J, Schauer T . IMU-based joint angle measurement for gait analysis. Sensors (Basel). 2014; 14(4):6891-909. PMC: 4029684. DOI: 10.3390/s140406891. View

3.
Mariani B, Rochat S, Bula C, Aminian K . Heel and toe clearance estimation for gait analysis using wireless inertial sensors. IEEE Trans Biomed Eng. 2012; 59(11):3162-8. DOI: 10.1109/TBME.2012.2216263. View

4.
Begg R, Best R, DellOro L, Taylor S . Minimum foot clearance during walking: strategies for the minimisation of trip-related falls. Gait Posture. 2006; 25(2):191-8. DOI: 10.1016/j.gaitpost.2006.03.008. View

5.
Azevedo Coste C, Sijobert B, Pissard-Gibollet R, Pasquier M, Espiau B, Geny C . Detection of freezing of gait in Parkinson disease: preliminary results. Sensors (Basel). 2014; 14(4):6819-27. PMC: 4029660. DOI: 10.3390/s140406819. View