» Articles » PMID: 26699006

Two-photon Imaging Through a Multimode Fiber

Overview
Journal Opt Express
Date 2015 Dec 25
PMID 26699006
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

In this work we demonstrate 3D imaging using two-photon excitation through a 20 cm long multimode optical fiber (MMF) of 350 µm diameter. The imaging principle is similar to single photon fluorescence through a MMF, except that a focused femtosecond pulse is delivered and scanned over the sample. In our approach, focusing and scanning through the fiber is accomplished by digital phase conjugation using mode selection by time gating with an ultra-fast reference pulse. The excited two-photon emission is collected through the same fiber. We demonstrate depth sectioning by scanning the focused pulse in a 3D volume over a sample consisting of fluorescent beads suspended in a polymer. The achieved resolution is 1 µm laterally and 15 µm axially. Scanning is performed over an 80x80 µm field of view. To our knowledge, this is the first demonstration of high-resolution three-dimensional imaging using two-photon fluorescence through a multimode fiber.

Citing Articles

Advantages of internal reference in holographic shaping ps supercontinuum pulses through multimode optical fibers.

Piscopo L, Collard L, Pisano F, Balena A, De Vittorio M, Pisanello F Opt Express. 2024; 32(14):24144-24155.

PMID: 39538862 PMC: 11595516. DOI: 10.1364/OE.528043.


Fiber-based imaging: unveiling avenues for exploring mechanisms of synaptic plasticity and neuronal adaptations underlying behavior.

Karpova A, Aly A, Marosi E, Mikulovic S Neurophotonics. 2024; 11(Suppl 1):S11507.

PMID: 38390518 PMC: 10883581. DOI: 10.1117/1.NPh.11.S1.S11507.


Wavefront shaping improves the transparency of the scattering media: a review.

Ding C, Shao R, He Q, Li L, Yang J J Biomed Opt. 2023; 29(Suppl 1):S11507.

PMID: 38089445 PMC: 10711682. DOI: 10.1117/1.JBO.29.S1.S11507.


110 μm thin endo-microscope for deep-brain in vivo observations of neuronal connectivity, activity and blood flow dynamics.

Stiburek M, Ondrackova P, Tuckova T, Turtaev S, Siler M, Pikalek T Nat Commun. 2023; 14(1):1897.

PMID: 37019883 PMC: 10076269. DOI: 10.1038/s41467-023-36889-z.


Learned end-to-end high-resolution lensless fiber imaging towards real-time cancer diagnosis.

Wu J, Wang T, Uckermann O, Galli R, Schackert G, Cao L Sci Rep. 2022; 12(1):18846.

PMID: 36344626 PMC: 9640670. DOI: 10.1038/s41598-022-23490-5.