Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation Towards Practical Non-Invasive Measurement of Blood Constituents

Overview
Journal PLoS One
Date 2015 Dec 5
PMID 26636974
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to compare conventional photoplethysmography (PPG) in a finger with PPG using an integrating sphere (ISPPG) to enhance scattered light collection. Two representative wavelengths were used; 1160 nm, a window through the absorption spectra of water and alcohol, and 1600 nm around where water absorption is high and there is an absorption peak of blood glucose. Simultaneous transmission-type measurements were made with conventional PPG and with ISPPG for each wavelength in the tips of index fingers of both hands in a total of 10 healthy young male and female volunteers (21.7 ± 1.6 years old). During a 5 min period in which subjects were in a relaxed state we determined the signal-to-noise ratio, SNR, and the PPG detectability (or sensitivity) by the two techniques. SNR during the test period was significantly higher with ISPPG as compared with conventional PPG, especially for the 1600 nm wavelength. PPG signals with 1600 nm could scarcely be detected by conventional PPG, while they could be detected with good sensitively by ISPPG. We conclude that under controlled conditions ISPPG has better SNR and higher sensitivity than conventional transmission PPG, especially in wavelength regions where water absorption is high but where there is potential for practical measurement of blood constituents including glucose.

Citing Articles

Noise-Robust Pulse Wave Estimation from Near-Infrared Face Video Images Using the Wiener Estimation Method.

Hino Y, Ashida K, Ogawa-Ochiai K, Tsumura N J Imaging. 2023; 9(10).

PMID: 37888309 PMC: 10607892. DOI: 10.3390/jimaging9100202.


Review of Ethanol Intoxication Sensing Technologies and Techniques.

Paprocki S, Qassem M, Kyriacou P Sensors (Basel). 2022; 22(18).

PMID: 36146167 PMC: 9501510. DOI: 10.3390/s22186819.


Device and Method for Noninvasive Glucose Assessment.

Segman Y J Diabetes Sci Technol. 2018; 12(6):1159-1168.

PMID: 29575926 PMC: 6232732. DOI: 10.1177/1932296818763457.

References
1.
Nilsson L . Respiration signals from photoplethysmography. Anesth Analg. 2013; 117(4):859-865. DOI: 10.1213/ANE.0b013e31828098b2. View

2.
Lopez Silva S, Dotor Castilla M, Silveira Martin J . Near-infrared transmittance pulse oximetry with laser diodes. J Biomed Opt. 2003; 8(3):525-33. DOI: 10.1117/1.1578495. View

3.
Maruo K, Tsurugi M, Tamura M, Ozaki Y . In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy. Appl Spectrosc. 2003; 57(10):1236-44. DOI: 10.1366/000370203769699090. View

4.
Yamakoshi K, Shimazu H, Togawa T . Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique. IEEE Trans Biomed Eng. 1980; 27(3):150-5. DOI: 10.1109/TBME.1980.326616. View

5.
Maeda Y, Sekine M, Tamura T . The advantages of wearable green reflected photoplethysmography. J Med Syst. 2010; 35(5):829-34. DOI: 10.1007/s10916-010-9506-z. View