Validation of Normalized Pulse Volume in the Outer Ear As a Simple Measure of Sympathetic Activity Using Warm and Cold Pressor Tests: Towards Applications in Ambulatory Monitoring

Overview
Journal Physiol Meas
Date 2013 Feb 28
PMID 23442846
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress.

Citing Articles

Investigation of Optimal Light Source Wavelength for Cuffless Blood Pressure Estimation Using a Single Photoplethysmography Sensor.

Toda S, Matsumura K Sensors (Basel). 2023; 23(7).

PMID: 37050747 PMC: 10098792. DOI: 10.3390/s23073689.


Challenges Presented by Cuffless Measurement of Blood Pressure if Adopted for Diagnosis and Treatment of Hypertension.

Avolio A, Cox J, Louka K, Shirbani F, Tan I, Qasem A Pulse (Basel). 2023; 10(1-4):34-45.

PMID: 36660438 PMC: 9843645. DOI: 10.1159/000522660.


Cuffless blood pressure estimation based on haemodynamic principles: progress towards mobile healthcare.

Yamakoshi T, Rolfe P, Yamakoshi K PeerJ. 2021; 9:e11479.

PMID: 34141472 PMC: 8183454. DOI: 10.7717/peerj.11479.


Cuffless blood pressure estimation using only a smartphone.

Matsumura K, Rolfe P, Toda S, Yamakoshi T Sci Rep. 2018; 8(1):7298.

PMID: 29740088 PMC: 5940836. DOI: 10.1038/s41598-018-25681-5.


Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.

Ding X, Yan B, Zhang Y, Liu J, Zhao N, Tsang H Sci Rep. 2017; 7(1):11554.

PMID: 28912525 PMC: 5599606. DOI: 10.1038/s41598-017-11507-3.