» Articles » PMID: 26625736

Techniques for Evaluation of LAMP Amplicons and Their Applications in Molecular Biology

Overview
Specialty Oncology
Date 2015 Dec 3
PMID 26625736
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Loop-mediated isothermal amplification (LAMP) developed by Notomi et al. (2000) has made it possible to amplify DNA with high specificity, efficiency and rapidity under isothermal conditions. The ultimate products of LAMP are stem-loop structures with several inverted repeats of the target sequence and cauliflower-like patterns with multiple loops shaped by annealing between every other inverted repeats of the amplified target in the similar strand. Because the amplification process in LAMP is achieved by using four to six distinct primers, it is expected to amplify the target region with high selectivity. However, evaluation of reaction accuracy or quantitative inspection make it necessary to append other procedures to scrutinize the amplified products. Hitherto, various techniques such as turbidity assessment in the reaction vessel, post-reaction agarose gel electrophoresis, use of intercalating fluorescent dyes, real-time turbidimetry, addition of cationic polymers to the reaction mixture, polyacrylamide gel-based microchambers, lateral flow dipsticks, fluorescence resonance energy transfer (FRET), enzyme-linked immunosorbent assays and nanoparticle-based colorimetric tests have been utilized for this purpose. In this paper, we reviewed the best-known techniques for evaluation of LAMP amplicons and their applications in molecular biology beside their advantages and deficiencies. Regarding the properties of each technique, the development of innovative prompt, cost-effective and precise molecular detection methods for application in the broad field of cancer research may be feasible.

Citing Articles

Advancements in LAMP-Based Diagnostics: Emerging Techniques and Applications in Viral Detection with a Focus on Herpesviruses in Transplant Patient Management.

Gomes Torres A, Mathias C, Baal S, Kohler A, Cunha M, Blanes L Int J Mol Sci. 2024; 25(21).

PMID: 39519059 PMC: 11546353. DOI: 10.3390/ijms252111506.


An accurate and convenient method for via one-step LAMP-CRISPR/Cas12b detection platform.

Liu T, Liu Q, Chen F, Shi Y, Maimaiti G, Yang Z Front Cell Infect Microbiol. 2024; 14:1409078.

PMID: 39176261 PMC: 11338869. DOI: 10.3389/fcimb.2024.1409078.


Recent advances in loop-mediated isothermal amplification (LAMP) for rapid and efficient detection of pathogens.

Garg N, Ahmad F, Kar S Curr Res Microb Sci. 2022; 3:100120.

PMID: 35909594 PMC: 9325740. DOI: 10.1016/j.crmicr.2022.100120.


A LAMP Assay for the Detection of , an Alien Gall Midge Species Pest of Pine Trees.

Jiao J, Ren L, Chen R, Tao J, Luo Y Insects. 2022; 13(6).

PMID: 35735877 PMC: 9225623. DOI: 10.3390/insects13060540.


Evaluation of the real-time fluorescence loop-mediated isothermal amplification assay for the detection of Ureaplasma urealyticum.

Shen J, Ye J, Lao M, Wang C, Wu D, Chen X AMB Express. 2022; 12(1):16.

PMID: 35147799 PMC: 8837760. DOI: 10.1186/s13568-022-01357-2.