Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

Overview
Journal PLoS One
Date 2015 Oct 29
PMID 26509265
Citations 175
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power.

Methods: 30 healthy young adults (age: 23±5 yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change.

Results: Comparison of RFD methods revealed that a peak 200 ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31-0.79).

Conclusions: Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations.

Citing Articles

Effect of Universal Exercise Unit Versus Functional Electrical Stimulation on Genu Recurvatum in Diplegic Cerebral Palsy Children.

Elsharkawy M, Sherif A, Sarhan E, El-Agamy O, Elsebahy S J Musculoskelet Neuronal Interact. 2025; 25(1):109-118.

PMID: 40024234 PMC: 11880854. DOI: 10.22540/JMNI-25-109.


Discussion on the validity of commonly used reliability indices in sports medicine and exercise science: a critical review with data simulations.

Warneke K, Gronwald T, Wallot S, Magno A, Hillebrecht M, Wirth K Eur J Appl Physiol. 2025; .

PMID: 39939564 DOI: 10.1007/s00421-025-05720-6.


Reliability and Agreement of Hand-Held Dynamometry Using Three Standard Rater Test Positions.

Aerts F, Sheets H, Anderson C, Bussie N, Hoskins R, Maninga A Int J Sports Phys Ther. 2025; 20(2):243-252.

PMID: 39906058 PMC: 11788088. DOI: 10.26603/001c.128286.


Acute effects of tissue flossing on boxers with chronic knee pain.

Chen J, Wang Q, Zhao Z, Song Q, Zhao P, Wang D Front Bioeng Biotechnol. 2025; 12:1508054.

PMID: 39877264 PMC: 11772274. DOI: 10.3389/fbioe.2024.1508054.


Assessing a clinical vital sign in severe mental illness: validation study of the 5 sit-to-stand test for monitoring muscle strength - The PsychiActive Project.

Lopez-Moral A, Munguia-Izquierdo D, Bueno-Antequera J BJPsych Open. 2025; 11(1):e24.

PMID: 39866000 PMC: 11823003. DOI: 10.1192/bjo.2024.842.


References
1.
Gerrits K, Beltman M, Koppe P, Konijnenbelt H, Elich P, de Haan A . Isometric muscle function of knee extensors and the relation with functional performance in patients with stroke. Arch Phys Med Rehabil. 2009; 90(3):480-7. DOI: 10.1016/j.apmr.2008.09.562. View

2.
Pua Y, Wrigley T, Wrigley T, Cowan S, Bennell K . Intrarater test-retest reliability of hip range of motion and hip muscle strength measurements in persons with hip osteoarthritis. Arch Phys Med Rehabil. 2008; 89(6):1146-54. DOI: 10.1016/j.apmr.2007.10.028. View

3.
Arnold C, Warkentin K, Chilibeck P, Magnus C . The reliability and validity of handheld dynamometry for the measurement of lower-extremity muscle strength in older adults. J Strength Cond Res. 2009; 24(3):815-24. DOI: 10.1519/JSC.0b013e3181aa36b8. View

4.
Poulsen E, Christensen H, Penny J, Overgaard S, Vach W, Hartvigsen J . Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis - an inter-rater study. BMC Musculoskelet Disord. 2012; 13:242. PMC: 3565957. DOI: 10.1186/1471-2474-13-242. View

5.
Kelln B, McKeon P, Gontkof L, Hertel J . Hand-held dynamometry: reliability of lower extremity muscle testing in healthy, physically active,young adults. J Sport Rehabil. 2008; 17(2):160-70. DOI: 10.1123/jsr.17.2.160. View