» Articles » PMID: 18503813

Intrarater Test-retest Reliability of Hip Range of Motion and Hip Muscle Strength Measurements in Persons with Hip Osteoarthritis

Overview
Date 2008 May 28
PMID 18503813
Citations 51
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To examine the relative and absolute intrarater test-retest reliability of muscle strength and range of motion (ROM) measurements of the hip performed in people with hip osteoarthritis.

Design: Repeated measures.

Setting: Human movement laboratory of a university.

Participants: Participants (N=22; 10 men, 12 women; age range, 50-84y) with hip osteoarthritis.

Interventions: On 2 separate occasions, at least 1 week apart, isometric torque measurements were obtained from the hip rotators, flexors, abductors, and extensors. Passive ROMs in hip rotation, flexion, abduction, and extension were also determined.

Main Outcome Measures: Relative reliability was estimated using the intraclass correlation coefficient, model 2,2 (ICC(2,2)). Absolute reliability was estimated using the coefficient of variation (CV) and the standard error (SE) of measurement.

Results: For measurements of muscle strength, ICC(2,2) ranged from .84 to .97, and the CV ranged from 8% to 15.7%. Hip extensors and internal and external rotators showed high ICC(2,2) (>.96) and low CV (<9.8%); hip abductors showed the lowest ICC(2,2) (.84) and the highest CV (15.7%). For ROM measurements, ICC(2,2) ranged from .86 to .97 and SE ranged from 3.1 degrees to 4.7 degrees . Hip flexion ROM showed the highest ICC(2,2) (.97) and an SE of 3.5 degrees ; hip extension ROM showed the lowest ICC(2,2) (.86) and the highest SE (4.7 degrees ).

Conclusions: Strength and ROM testing of the hip in people with hip osteoarthritis can be performed with good to excellent reliability.

Citing Articles

The Impact of Spinopelvic and Hip Mobility on Passive Hip Flexion Range of Motion Assessment.

Tokuyasu H, Tsushima E, Takemoto M, Vergari C, Tada H, Kim Y Arthroplast Today. 2024; 29:101429.

PMID: 39328882 PMC: 11424763. DOI: 10.1016/j.artd.2024.101429.


Nonsurgical Management of Adductor-related groin pain with Ultrasound-Guided Platelet-Rich Plasma Injection and Physical Therapy in a Competitive Soccer Player: A Case Report.

Zeppieri G, Smith M, Roach R Int J Sports Phys Ther. 2024; 19(7):898-909.

PMID: 38966832 PMC: 11221341. DOI: 10.26603/001c.120209.


Muscle Strength and Joint Range of Motion of the Spine and Lower Extremities in Female Prepubertal Elite Rhythmic and Artistic Gymnasts.

Mandroukas A, Metaxas I, Michailidis Y, Metaxas T J Funct Morphol Kinesiol. 2023; 8(4).

PMID: 37987489 PMC: 10660469. DOI: 10.3390/jfmk8040153.


The pattern of collagen production may contribute to the gluteal muscle contracture pathogenic process.

Jiang X, Zhang H, Ren Y, Yang L, Zhong L, Guo J J Orthop Surg Res. 2023; 18(1):579.

PMID: 37550712 PMC: 10408206. DOI: 10.1186/s13018-023-04069-w.


Effect of Ultrasound-Guided Percutaneous Neuromodulation of Sciatic Nerve on Hip Muscle Strength in Chronic Low Back Pain Sufferers: A Pilot Study.

San-Emeterio-Iglesias R, De-la-Cruz-Torres B, Romero-Morales C, Minaya-Munoz F J Clin Med. 2022; 11(22).

PMID: 36431149 PMC: 9693530. DOI: 10.3390/jcm11226672.